Assembly; Installation - Craftsman PERMANENTLY LUBRICATED TANK MOUNTED AIR COMPRESSOR 919.167321 Owner's Manual

Permanently lubricated tank mounted air compressor
Table of Contents

Advertisement

Available languages

Available languages

Unpacking
1.
Remove unit from carton and discard all packaging.
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
Locate the air compressor in a
clean, dry and well ventilated
area.
The air compressor should be
located at least 12" (30.5 cm)
away from the wall or other
obstructions that will interfere
with the flow of air.
The air compressor pump and
shroud are designed to allow for
proper cooling. The ventilation
openings on the compressor are
necessary to maintain proper
operating temperature. Do not
place rags or other containers on
or near these openings.
GROUNDING INSTRUCTIONS
of a short circuit, grounding reduces
the risk of shock by providing an
escape wire for the electric current.
This air compressor must be
properly grounded.
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following
illustrations).
1.
The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
IMPORTANT: The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
A17883

ASSEMBLY

INSTALLATION

Risk of Electrical
Shock. In the event
2.
Make sure the outlet being used
has the same configuration as the
grounded plug. DO NOT USE AN
ADAPTER. See illustration.
Plug
Grounding Pin
3.
Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
4.
If these grounding instructions are
not completely understood, or if in
doubt as to whether the compres-
sor is properly grounded, have the
installation checked by a qualified
electrician.
GROUNDING CAN RESULT IN
ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed by
a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified
electrician.
10 - ENG
Grounded
Outlets
Risk of Electrical
Shock. IMPROPER