  • Page 1 RTP900 TRANSFER PUMP...
  • Page 2 DESCRIPTION Components List 1. 25mm Water inlet 2. Pre-Filter 3. 25mm Water outlet 4. Drain plug 5. Pump Head 6. On/Off switch 7. Carry Handle 8. 900W Induction motor with thermal overload 9. Spanner 10. Thread seal tape...
  • Page 3 DESCRIPTION 30cm 30cm Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8...
  • Page 4 DESCRIPTION Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14...
  • Page 5 Important! It is essential that you read the instructions in this manual before assembling, operating and maintaining the product. Subject to technical modification.
  • Page 6: General Safety Warnings

    ■ Keep handles and grasping surfaces dry, clean GENERAL SAFETY WARNINGS and free from oil and grease. Slippery handles ■ Read all safety warnings and all instructions. and grasping surfaces do not allow for safe handling Failure to follow the warnings and instructions and control of the tool in unexpected situations.
  • Page 7: Maintenance

    ■ Do not install or operate the water pump in an NOTE: Do not use abrasive cleaning agents to clean explosive environment or near flammable material. the filter. ■ Do not operate the water pump without liquid. 1. Once clean re-assemble the pre-filter. ■...
  • Page 8: Specifications

    3. All water pipe joints must be sealed with minimal MAINTENANCE MANUAL elbow connections for best performance. Clean strainer mesh (Fig. 13) 4. Monitor water level decline when using, and bottom To maintain optimum water flow performance, users valve should remain submerged. should clean strainer mesh components regularly 5.
  • Page 9 COMMON FAILURES AND TREATMENT Failures Causes Measures Turn off pump and refill pump chamber with Water pump is not primed (not filled with water) water No water output Water level is lower than bottom valve Adjust water inlet pipeline to submerge bottom from pump valve Leakage of suction pipes...