  • Page 1 RSSS750 / RSSS1000 750W/1000W STAINLESS STEEL SUBMERSIBLE PUMP RSSS750 RSSS1000...
  • Page 2 DESCRIPTION RSSS750 Components List 1. Water outlet 2. Pump base 3. Suction port 4. Floating switch 5. Cable of floating switch 6. Cable holder 7. Carry handle 8. Power cable 9. Pressure relief valve 10. Pump housing 11. Right angle adaptor...
  • Page 3 DESCRIPTION RSSS750 Components List 1. Water outlet 2. Pump base 3. Suction port 4. Floating switch 5. Cable of floating switch 6. Cable holder 7. Carry handle 8. Power cable 9. Pressure relief valve 10. Pump housing 11. Right angle adaptor 12.
  • Page 4 DESCRIPTION 30° 30° Fig. 1 Fig. 2 PUSH START 100mm minimum STOP Fig. 3 Fig. 4...
  • Page 5 Important! It is essential that you read the instructions in this manual before assembling, operating and maintaining the product. Subject to technical modification.
  • Page 6: General Safety Warnings

    ■ W h e n s e r v i c i n g t h e p r o d u c t , u s e o n l y GENERAL SAFETY WARNINGS manufacturer’s replacement parts, accessories ■ Read all safety warnings and all instructions. and attachments.
  • Page 7: Maintenance

    INTENDED USE ■ The pump must not be used when people are in the ■ RYOBI Submersible dirty water pumps are highly water. efficient electrical pumps for discharging clear or ■ Never work or perform maintenance on the pump...
  • Page 8: Electrical Connection

    INSTALLATION OF THE PRESSURE LINE selfpriming level is not fallen short of. If everything The pressure line conveys the liquids to be discharged is properly set, the water level may decrease from the pump to the point of withdrawal. To avoid down to the minimum suction level once the pump dynamic flow losses, one should use a pressure line is operating.
  • Page 9: Maintenance And Troubleshooting

    Any repair beyond the scope specified below ■ The electrical RYOBI pumps are equipped with must only be performed be qualified staff. Please an integrated thermal motor protection feature.
  • Page 10: Specifications

    SPECIFICATIONS RSSS750 Rated Power 750W Max Head Max. Immersion Depth Max. Water Flow 17,000L/hr Max. Working Temp. 35ºC Max. Particle Size 35mm Cable Length RSSS1000 Rated Power 1000W Max Head 10.5m Max. Immersion Depth Max. Water Flow 19,500L/hr Max. Working Temp.
  • Page 11 COMMON FAILURES AND TREATMENT Malfunction Possible cause Elimination Thermal motor protection feature has Separate the pump from the electrical triggered. (for information on operation with mains, allow the system to cool down, liquids > 50°C, see the note in Technical eliminate cause.