Page 7
This pump is designed to transfer clean water. Never attempt using this pump to deliver dirty water or slurry, or any inflammable or corrosive liquids. Do not touch the hot muffler while the machine is working. Move the machine when it's stopped and cooled down.
PRE-STARTING OPERATION Checking and filling the pump with cooling water The pump must be fully filled with priming water before it IMPORTANT: Install the strainer on the end of the is put to operation. (Fig. 5) suction hose before operation. The strainer prevents foreign materials and protects the pump from block STARING THE ENGINE and component damages.
Cleaning filter element: MAINTENANCE Slightly tap the filter element a few times, then blow it with compressed air (pressures 207 KPa) from inside. Do not clean the filter element with brush, which will block the air passages of the element. Cleaning foam filter element: Wash the element in hot water with detergent or in a non flammable or high flash point solvent.
Page 10
4. Is the engine switch ON? 5. Is there enough engine oil or does the oil exceed the upper level? Motor 196cc 4-Stroke OHV 6. Is the spark plug generating sparks? Max. Flow Rate 30,000L/hr Uninstall and check the spark plug, clear off the dirt from Max.