NOTE: The adjustments made for Red / Green / Blue are
stored separately for each IRE setting. (There are ten IRE
settings from 10 to 100.)
Colour Calibration
The aim of Colour Calibration is to measure and/or adjust the
colour response (White Balance) of your LCD panel.
Colour Calibration is used by various fields, such as gaming,
photography, engineering, medical and more. In order to
calibrate a display correctly, you need a colour analyzer TPA-1
(not supplied).
NOTE: This feature is available when the Picture Mode option
is Hollywood Pro.
Apply Calibration
a
In the Expert Picture Settings menu, press
select Colour Calibration and press OK.
b
B
b
Press
or
to select Apply Calibration and press
c
or
to select Enable.
Manual Colour Calibration
a
In the Colour Calibration menu, press
select Manual Colour Calibration and press OK.
Manual Colour Calibration
Please input the value measured with the coulour analyser.
x
y
Red
0.642
0.335
Green
0.277
0.603
Blue
0.143
0.067
Start
Reset
b
Place the probe of the colour analyzer over the square
on screen to measure.
c
Input the value measured with the colour analyzer
using the number buttons (0-9).
x
Red
0.642
Green
0.277
Blue
0.143
d
BbC c
Press
and input the values to fill all RGBxy
matrix table.
e
Highlight Start and press OK.
Please wait until you see "Manual Colour Calibration
has been completed." on screen.
To return to factory setting
a
Highlight Reset and press OK.
B
b
or
B
b
or
to
y
0.335
0.603
0.067
Auto Colour Calibration
a
In the Colour Calibration menu, press
select Auto Colour Calibration and press OK.
b
Connect the USB colour analyzer to the USB 1 or USB
2 port.
c
Place the probe of the USB colour analyzer over the
square on screen and press OK.
Auto Colour Calibration will start.
Please wait until you see "Auto Colour Calibration has
been completed.".
Gamma Calibration
to
a
In the Expert Picture Settings menu, press
select Gamma Calibration and press OK.
C
b
B
b
Press
or
c
or
to select Enable.
c
B
b
Press
or
press OK.
d
Connect the USB colour analyzer to the USB 1 or USB
2 port.
e
Input the target value and place the USB colour
analyzer over the square on screen.
Auto Gamma Calibration
Please input the target value and place the USB colour analyser
over the square.
Target Colour Temperature
Target Gamma
f
Highlight Start and press OK.
Auto Gamma Calibration will start.
Please wait until you see "Auto Gamma Calibration
has been completed." on screen.
To return to factory setting
a
Highlight Reset and press OK.
Resetting to the factory defaults
a
In the Expert Picture Settings menu, press
select Reset and press OK.
A confirmation screen appears.
b
Select Yes and press OK.
45
CONTROLS AND FEATURES
B
to select Apply Calibration and press
to select Auto Gamma Calibration and
x
y
0.313
0.329
2.4
Start
Reset
b
or
to
B
b
or
to
C
B
b
or
to