ABB ACS880-01 User Manual page 9

Hide thumbs Also See for ACS880-01:
Table of Contents

Advertisement

8
User's manual – ACS880 01 democase
Parameters that need to be changed
Parameter
Name
95
HW configuration
95.01
Supply voltage
91
Encoder module settings
91.11
Module 1 type
91.12
Module 1 location
92
Encoder 1 configuration
92.01
Encoder 1 type
92.02
Encoder 1 source
92.10
Pulses/revolution
92.12
Speed calculation mode
92.13
Position estimation enable
92.15
Transient filter
92.20
Enc cable fault func
After setting feedback parameters, activate settings with
91
Encoder 1 configuration
91.10
Encoder parameter refresh
90
Feedback selection
90 .41
Motor feedback selection
I/O settings
12
Standard AI
12.25
AI2 unit selection
12.28
AI2 max
Motor parameters and ID-run
99
Motor data
99.03
Motor type
99.04
Motor ctrl mode
99.06
Motor nominal current
99.07
Motor nominal voltage
99.08
Motor nominal frequency
99.09
Motor nominal speed
99.10
Motor nominal power
99.11
Motor nominal cosfii
99.13
Identification run request
Setting
[2] 380...415 V
[4] FEN-31
003
[5] HTL
[1] Module 1
1024
[0] A&B all
[0] Disable
[2] 1220 Hz
[0] No
[1] Configure
[1] Encoder 1
[2] V
10
[0] Asynchronous
motor
[0] DTC
1.2 A
230 V
50 Hz
1360 rpm
0.18 kW
0.71
[1] Normal
ac.maher.co.ir
Notes
Correct rating settings made
FEN-31 location in Option slot 3
Will return to ' Done' after refresh
Start ID-run in ' Remote' : Press DI1 ,
in ' Local' : Press panel Start button

Advertisement

Table of Contents
loading

Table of Contents