Electrical Schematic – 460VAC, 3 phase
(Contact factory to request certified drawings)
20
21
LOW TENSION
ENCLOSURE
72
L
21
L
N
N
+12VDC
PE
TB5
PE
20
20
RED
+12VDC
21
21
BLACK
DC COM
80
RTD1+
81
RTD1–
70
ANLG1+
249 OHM
1/8W
ANLG1–
72
ANLG2+
21
21
ANLG2–
10
+5VDC
11
DC COM
RTD2+
RTD2–
84
RTD3+
85
RTD3–
86
RTD4+
87
RTD4–
88
RTD5+
89
RTD5–
90
IN1
91
32
LPS
33
LPS
34
RPS
35
RPS
IN2
IN3
50
L PURGE
+
51
L PURGE
52
R PURGE
+
53
R PURGE
54
L DRY
+
55
L DRY
56
R DRY
+
57
R DRY
110
OUT1
101
59
OUT2
20
+
NO
ALARM
NC
20
CONTACTS
+12VDC
C
TRANSFORMER VOLTAGES
CONNECT TO LINE FOR RESPECTIVE VOLTAGE
H1 - H2
H1 - H3
H1 - H4
208
220
380
440
230
400
460
240
416
480
38
DETAIL A
(2-WIRE DEWPOINT TRANSMITTER)
+12VDC
EXTERNALLY LOCATED
DEWPOINT
RED
20
3
TRANSMITTER
21
+ 4-20MA OUT
1
249 OHM
1/8W
BLACK
21
3-WIRE DEWPOINT TRANSMITTER
(FOR 2-WIRE, SEE DETAIL A)
EXTERNALLY LOCATED
DEWPOINT
3
TRANSMITTER
G
EXTERNALLY
+ 4-20MA OUT
1
LOCATED
ENERGY MGMT
OPTION
GREEN
SENSOR
RTD4
BROWN
BLACK
+
1-5VDC OUT
GREEN
RED
+
5VDC
ORANGE
G
OPTION
HEATER OVERTEMPERATURE
RTD3
RTD
RIGHT CHAMBER
RTD2
RTD
LEFT CHAMBER
RTD1
RTD
SOLENOIDS "C" AND "D"
FOR MODELS 300-750 ONLY
SOLENOID "C"
SOLENOID "D"
SOLENOID "B"
SOLENOID "A"
120VAC
102
SOLENOID "E"
101
SOLENOID "E"
FOR MODELS 900-3200 ONLY
21
OUTPUT VOLTS
H1 - H5
X1 - X2
500
85
550
91
575
95
600
99
L1
CUSTOMER PROVIDED
L2
460VAC, 3 PHASE
L3
(FOR FUSING SEE TABLE)
101
101
101
3PS
101
104
SET @ 10 PSIG
+12VDC
2CR1
20
3
3CR1
20
3
YELLOW
4CR1
20
3
+12VDC
4CR2
90
91
6
5
33
32
1PS
SET @ 45 PSIG
35
34
2PS
SET @ 45 PSIG
FOR MODELS 900-3200 ONLY
2CR
+
50
51
8
1
3CR
+
52
53
8
1
1CR
+
59
8
1
X1 - X3
X1 - X4
100
110
110
120
115
125
120
130
HC
401
HC1
402
HC2
403
HC3
0.5 AMP
2FU
L2
404
1FU
0.5 AMP
1T
L1
405
PRIMARY
H1
H2
H3
H4
X4
X3
X2
X1
1.25 AMP
SECONDARY
3FU
101A
+12VDC
21
20
+V
-V
102
101
L
N
G
PS
K TYPE
1TC
+
101
102
1CR1
L1
N
4PS
106
107
105
3
4
C
NO
SET @ 20 PSIG
FALLING
104
8
ADD FOR MODELS 900-3200 ONLY
SOLENOID "F"
27
4
SOLENOID "G"
28
4
2CR2
SOLENOID "C"
22
23
4
6
5
3CR2
SOLENOID "D"
22
24
6
5
~
~
1CR2
SOLENOID "H"
22
26
26
6
5
ON DRYER
ADD FOR PURGE SAVER OPTION
LEFT CHAMBER
PRESSURE SWITCH
RIGHT CHAMBER
PRESSURE SWITCH
HEAT ENABLE
21
HIGH TENSION
ENCLOSURE
HEATER
MODEL
KW
300
5.0
400
7.0
500
7.0
600
8.0
750
10.0
900
12.0
1050
14.0
1300
17.0
1500
19.0
1800
23.0
2200
27.5
2600
32.0
3200
39.0
1HTR
NOTE:
VERIFY TRANSFORMER IS
WIRED FOR THE VOLTAGE
REQUIRED BY DRYER.
H5
(REFER TO TRANSFORMER CHART)
102
21
102
102
102
HC
4CR
102
1
DC COM
21
LEFT CHAMBER DEPRESS
21
RIGHT CHAMBER DEPRESS
21
LEFT CHAMBER PURGE
EXHAUST
21
RIGHT CHAMBER PURGE
EXHAUST
~
~
21
PURGE SAVER INTAKE
SHUTOFF VALVE
21
DC COM
F.L.A.
SUGGESTED
@480VAC
LD. CENTER
6.01
10 AMPS
8.80
15 AMPS
8.80
15 AMPS
9.62
15 AMPS
12.02
20 AMPS
14.43
20 AMPS
16.85
25 AMPS
21.34
30 AMPS
22.85
30 AMPS
27.66
35 AMPS
33.07
45 AMPS
38.49
50 AMPS
46.91
60 AMPS