2. Range of use

Rain-water pumps from T.I.P. are highly efficient electrical pumps for discharging clear, clean or moderately dirty
water containing solids up to the maximum size specified in the technical details.
The typical ranges of application of rain-water pumps include: Emptying rain barrels and similar containers, filling
watering cans and irrigation using a connected shower head.
Rain-water pumps from T.I.P. are suitable for stationary or temporary installations.
This product is intended for private use in the home area and not for commercial or industrial purposes or for
continuous circulating.
The device is not suitable for use in swimming pools or for installation in public water mains.
The pump is not suitable for use in table-top fountains, aquariums or similar ranges of use.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.

3. Technical Data

Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
2)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
The values between brackets refer to the illustrations given at the end of these operating instructions.
2)

4. Scope of delivery

The scope of the delivery of this product includes:
One pump with connection cable, an outlet element with a stopcock, three riser-pipe segments, seals, one
fastening clamp, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
DIO 45/13 flex
230 V~ 50 Hz
350 Watt
IPX8
"), male
26.44 mm
¾
(
2,700 l/h
1.3 bar
13 m
5 m
2 mm
35 °C
30, evenly distributed
10 m
H05RN-F
~ 4.2 kg
55 mm
20 mm
330 mm
150 mm
16.5 x 15.5 x 26.5 cm
30263
2
9