ELECTRICAL SPECIFICATIONS

Function
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Capacitance
Frequency
Duty Cycle
Temp (type-K)
(probe accuracy not included)
NOTE: No Auto Ranging & 400mV AC Voltage Range
Range
& Resolution
40.00 AAC
± (2.8% + 10 digits)
400.0 AAC
± (2.8 % + 5 digits)
1000 AAC
± (3.0 % + 5 digits)
40.00 AAC
± (3.0% + 10 digits)
400.0 AAC
± (3.0 % + 5 digits)
1000 AAC
± (3.0 % + 5 digits)
400.0 mVDC
± (0.8% + 3 digits)
4.000 VDC
40.00 VDC
± (1.5% + 3 digits)
400.0 VDC
600 VDC
± (2.0% + 3 digits)
400.0 mVAC
± (0.8% + 20 digits)
4.000 VAC
40.00 VAC
± (1.8% + 5 digits)
400.0 VAC
600 VAC
± (2.5% + 5 digits)
400.0 Ω
± (1.0% + 4 digits)
4.000KΩ
40.00KΩ
± (1.5% + 2 digits)
400.0KΩ
4.000MΩ
± (2.5% + 3 digits)
40.00MΩ
± (3.5% + 5 digits)
± (5.0% reading + 100
40.00nF
digits)
400.0nF
± (3.0% reading + 5 digits)
4.000μF
± (3.5% reading + 5 digits)
40.00μF
100.0μF
± (5.0% reading + 5 digits)
5.000Hz
± (1.5% reading + 5 digits)
50.00Hz
500.0Hz
± (1.2% reading + 2 digits)
5.000kHz
Sensitivity: 10Vrms min.
50.00kHz
100.0kHz
0.5 to 99.0%
± (1.2% reading + 2 digits)
Pulse width: 100μs - 100ms, Frequency: 5.000Hz ~
100.0kHz
-20 to 1000°C
± (3.0% reading + 5°C)
-4 to 1832°F
± (3.0% reading + 7°F)
Accuracy
(% of reading)