Battery Power - Chauvet DJ EZLink Par Q6BT ILS Quick Reference Manual

Hide thumbs Also See for EZLink Par Q6BT ILS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Power Linking
It is possible to link up to 17 EZLink Par Q6BT ILS products at 120 V or 31 products at 230 V. Never exceed this number.
Power-linking cords can be purchased separately.
Fuse Replacement
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the safety cap out of the housing.
4.
Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same
type and rating.
5.
Re-insert the fuse holder and reconnect power.

Battery Power

The EZLink Par Q6BT ILS comes with a rechargeable lithium battery for cable free operation.
Charging the Battery
The battery charges whenever the EZLink Par Q6BT ILS is plugged into a power source using the included power cord. If
the product is plugged in and not in operation, make sure the product is turned off.
The LED indicator light will flash if you overcharge your units.
DO NOT use the EZLink Par Q6BT ILS on full power mode (all LEDs at 100%) while being
charged/plugged into a power source, as the unit will get extremely hot.
Battery Life Indicator
The indicators on the LED Menu Display show how much battery life remains available. The drawing below provides a
key to reading the battery life indicators.
100%
Battery Run Time
Maximum Run Time (all colors on)
Up to 8 hours
EZLink Par Q6BT ILS QRG Rev. 1
QUICK REFERENCE GUIDE
75%
Maximum Run Time (single color on)
Up to 20 hours
50%
25%
EN
Recharge Time
4 hours