Table 38.
Obj n° Value
536
537
538
539
540
541
542
543
577
545
546
547
548
549
550
551
553
554
555
580
106
509
994
995
996
997
Table 39.
Obj n° Value
154
156
990
991
992
993
542
543
996
997
28
Installation, Operation and Maintenance Manual
Torque Sensor
Function
700
F01tor op 100%
600
F01tor op 50%
400
F01tor op 50%
300
F01tor op 100%
500
I2tor op 0% +5%
450
I2tor op 40% +5%
400
I2tor op 70% +5%
300
I2tor op 100% +5%
10
Gears ratio
440
I2tor op 40% -5%
390
I2tor op 70% -5%
290
I2tor op 100% -5%
600
I2tor cl 0% +5%
550
I2tor cl 40% +5%
500
I2tor cl 70% +5%
450
I2tor cl 100% +5%
540
I2tor cl 40% -5%
490
I2tor cl 70% -5%
430
I2tor cl 100% -5%
400
I2tor voltage
50 Hz
I2tor freq.
2
I2tor Ktemp
70
Torque-set CL (XTE)
70
Torque-set OP (XTE)
70
Torque-set CL (F01)
70
Torque-set OP (F01)
Function
f5000
Valve tag name
q234f
Valve serial number
-
Manufacturer
-
Break-OP torque
-
Max. stem thrust
-
Flange type
400
I2tor op 70% +5%
300
I2tor op 100% +5%
70
Torque-set CL (F01)
70
Torque-set OP (F01)
Nameplate
Description
Value of potentiometer at 100% of opening torque, in F01.
Not used for XTE3000
Value of potentiometer at 50% of opening torque, in F01.
Not used for XTE3000
Value of potentiometer at 50% of closing torque, in F01.
Not used for XTE3000
Value of potentiometer at 100% of closing torque, in F01.
Not used for XTE3000
Opening speed with torque 0% and voltage +5% of nominal
Opening speed with torque 40% and voltage +5% of nominal
Opening speed with torque 70% and voltage +5% of nominal
Opening speed with torque 100% and voltage +5% of nominal
Reduction ratio of gears, from 1 to 1000
Opening speed with torque 40% and voltage -5% of nominal
Opening speed with torque 70% and voltage -5% of nominal
Opening speed with torque 100% and voltage -5% of nominal
Closing speed with torque 0% and voltage +5% of nominal
Closing speed with torque 40% and voltage +5% of nominal
Closing speed with torque 70% and voltage +5% of nominal
Closing speed with torque 100% and voltage +5% of nominal
Closing speed with torque 40% and voltage -5% of nominal
Closing speed with torque 70% and voltage -5% of nominal
Closing speed with torque 100% and voltage -5% of nominal
Voltage of torque calibration, from 0 to 1000 V
50 Hz, 60 Hz, frequency of torque calibration
Temperature compensation, from 1 to 20
Value of torque set in factory
Value of torque set in factory
Value of torque set in factory. Not used for XTE3000
Value of torque set in factory. Not used for XTE3000
Valve Data
Description
Max. 28 characters
Max. 28 characters
Max. 28 characters
Max. 28 characters
Max. 28 characters
Max. 28 characters
Opening speed with torque 70% and voltage +5% of nominal
Opening speed with torque 100% and voltage +5% of nominal
Value of torque set in factory. Not used for XTE3000
Value of torque set in factory. Not used for XTE3000
MDE 257 Rev. 1
°"