Emerson Bettis XTE3000 Maintenance Instruction page 29

Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
MDE 257 Rev. 1
Table 25.
Obj n°
148
173
105
4
134
146
720
721
722
723
161
162
163
164
165
424
170
171
172
707
238
576
533
420
429
430
431
815
803
804
805
806
133
135
°"
Alarm "Configuration n
Reserved
Value
Function
Icon
SW type
I24 V4
Terminal board type
Mask
Additional variables
Auto
Backlight
1.5
Reversal delay
200
Volt span bit
650
4 mA in
3500
20 mA in
650
4 mA out
3500
20 mA out
451
Curr sens 2 A
382
Curr sens 3.5 A
387
Curr sens 7 A
443
Curr sens 15 A
441
Curr sens 30 A
10
Speed filter
1
Base heater reference
-2
LCD heater reference
-1
Terminal board heater reference
Disable
Sleep mode
Off
MR in SLEEP
Standard Torque function
Standard Interlock mode
Disable
New FW
Disable
Serial CMD
Disable
Loc/Rem
s/n°
Bluetooth code
75
EFS-duty %
Close
Spring action
On
EFS electrical CMD
PST
ESD input mode
Absent
EFS signal type
0
CMD-Filter
0
ESD-INT Filter
Section 4: Alarm "Configuration n°"
Actuator Setup
Description
XTE, F01
I24 V4, 5 relays, 8/9 relays, 12 relays, I24 Gold PR
Mask, view
Auto, on
Reversal delay, from 0 to 5.5 s (standard > 1)
Voltage span in bit, can only be read
Bit corresponding to 4 mA input
Bit corresponding to 20 mA input
Bit corresponding to 4 mA output
bit corresponding to 20 mA output
Bits when current is 2 A
Bits when current is 3.5 A
Bits when current is 7 A
Bits when current is 15 A
Bits when current is 30 A
From 0 to 255
°C reference of heater on base card,
from -40 to 50 °C
°C reference of heater on diplay card,
from -40 to 50 °C
°C reference of heater on terminal board,
from -40 to 50 °C
Enable, disable SLEEP function
On/off of monitor relay in sleep mode
Mode to evaluate torque, standard or advanced
Standard or advanced (local+interlock OP/CL)
Disable or enable, set to "enable" to download a new
firmware.
Disable or enable OP/CL/ST commands by BLT or serial
RS232
Enable or disable "Local + Remote" control mode
Select Bluetooth code or valve tag
Duty of EFS clutch (used only in EFS actuator). Not used
for XTE3000.
Actuator movement under
Enable/disable of electrical CMD in direction of safe
action. Not used for XTE3000.
Selector of ESD input of actuator, PST or EFS (electrical)
CMD. Not used for XTE3000.
Option Absent/present in case of ESD input used as EFS
CMD. Not used for XTE3000.
From 0 to 30 filter of OP/CL/ST commands signals
From 0 to 30 filter of ESD/INT commands signal