Electrical Connection; General Notes; Connecting The Indoor Unit; Connecting The Outdoor Unit - Bosch CL3000iU W 35 E Installation Instructions Manual

Split air conditioner
Hide thumbs Also See for CL3000iU W 35 E:
Table of Contents

Advertisement

3.5

Electrical connection

3.5.1

General notes

WARNING
Risk to life from electric shock!
Touching live electrical parts can cause an electric shock.
▶ Before working on electrical parts, disconnect all phases of the
power supply (fuse/circuit breaker) and lock the isolator switch to
prevent unintentional reconnection.
▶ Work on the electrical system must only be carried out by an
authorised electrician.
▶ Observe safety measures according to national and international
regulations.
▶ If you identify a safety risk in the mains voltage, or if a short circuit
occurs during installation, inform the operator in writing and do not
install the appliances until the problem has been resolved.
▶ All electrical connections must be made in accordance with the
electrical connection diagram.
▶ Only use a special tool to cut cable insulation.
▶ Do not connect any additional consumers to the mains power supply
of the device.
▶ Do not mix up live and null wires. This can lead to malfunctions.
▶ If the mains power supply is fixed, install an overvoltage protector
and isolator which is designed for 1.5 times the maximum power
input of the appliance.
▶ For devices with a fixed mains power supply in which the leakage
current is potentially higher than 10 mA, we recommend installing a
residual current device (RCD) with a maximum rated residual
operating current of 30 mA.
3.5.2

Connecting the indoor unit

The indoor unit is connected to the outdoor unit using a 5-core
communication cable of the type H07RN-F. The conductor cross-section
of the communication cable should be at least 1.5 mm
NOTICE
Material damage due to incorrectly connected indoor unit
Voltage is supplied to the indoor unit via the outdoor unit.
▶ Only connect the indoor unit to the outdoor unit.
To connect the communication cable:
▶ Fold up the top cover ( Fig. 19).
▶ Undo screw and remove cover of the interface panel.
▶ Remove screw and cover [1] of the terminal ( Fig. 20).
▶ Knock out an opening for the cable feed [3] on the rear of the indoor
unit and feed the cable through.
▶ Secure cable to the strain relief [2] and connect to the terminals W,
1(L), 2(N), S and
.
▶ Note assignment of wires to the terminals.
▶ Reattach the covers.
▶ Route the cable to the outdoor unit.
Climate 3000i – 6721823680 (2022/10)
3.5.3
A power cable (3-core) is connected to the outdoor unit and the
communication cable is connected to the indoor unit (5-core).
Use cables of the type H07RN-F with sufficient conductor cross-section
and protect the mains power supply with a fuse ( Table 8).
Outdoor unit
CL3000i 26 E
CL3000i 35 E
CL3000i 53 E
CL3000i 70 E
Table 8
▶ Undo the screw and remove the cover of the electrical connection
( Fig. 21).
▶ Secure the communication cable to the strain relief and connect to
the terminals W, 1(L), 2(N), S and
terminals same as indoor unit) ( Fig. 22).
▶ Secure power cable to the strain relief and connect to the terminals
L, N and
▶ Reattach cover.
2
.

Connecting the outdoor unit

Mains fuse
protection
Power cable Communication
13 A
≥ 1.5 mm
13 A
≥ 1.5 mm
16 A
≥ 1.5 mm
25 A
≥ 2.5 mm
.
Installation
Conductor cross-section
cable
2
2
≥ 1.5 mm
2
2
≥ 1.5 mm
2
2
≥ 1.5 mm
2
2
≥ 2.5 mm
(assignment of wires to
59

Advertisement

Table of Contents
loading

Table of Contents