Bosch Climate 3000i Installation Instructions Manual

Bosch Climate 3000i Installation Instructions Manual

Split air conditioner

Advertisement

Quick Links

Climate 3000i
CL3000i-Set 26 E | CL3000i-Set 35 E | CL3000i-Set 53 E | CL3000i-Set 70 E
bg
Климатична сплит система
cs
Splitová klimatizační jednotka
da
Split-klimaanlæg
de
Split-Klimagerät
el
Κλιματιστικό Split _type
en
Split air conditioner
es
Climatizador split
fr
Climatiseur split
hr
Mono split klima-uređaj
hu
Split klímakészülék
it
Condizionatore split
mk
Сплит клима уред
nl
Split-airconditioning
pl
Urządzenie klimatyzacyjne split
pt
Aparelho de ar condicionado Split
ro
Aparat de aer condiționat
sl
Split klimatska naprava
sq
Kondicioner Split
sr/cnr Split klima uređaj
tr
Split tipi klima cihazı
uk
Спліт кондиціонер
Ръководство за монтаж . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Návod k instalaci . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installationsvejledning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installationsanleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Οδηγίες εγκατάστασης. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Manual de instalación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Notice d'installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Upute za instalaciju . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Szerelési útmutató . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Istruzioni per l'installazione . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Упатства за монтажа . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Installatie-instructie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Instrukcja montażu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Instruções de instalação. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Instrucțiuni de instalare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Navodila za namestitev . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Kondicioner Split. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Uputstvo za instalaciju . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Montaj kılavuzu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Інструкція з монтажу та технічного обслуговування. . . . . . . . . . . . . . . . . . . . . . . . 207
0010032905-001

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Climate 3000i

  • Page 1 Climate 3000i CL3000i-Set 26 E | CL3000i-Set 35 E | CL3000i-Set 53 E | CL3000i-Set 70 E Климатична сплит система Ръководство за монтаж ..........2 Splitová...
  • Page 2: Table Of Contents

    Technical Data ........63 Climate 3000i – 6721823680 (2021/02)
  • Page 3: General Safety Instructions

    ▶ Do not to let any other substance than the specified contains references to the figures. refrigerant (R32) into the refrigerant cycle. Depending on the model, the products may be different to those shown in these instructions. Climate 3000i – 6721823680 (2021/02)
  • Page 4: Product Information

    ▶ Take minimum room area into account. CL3000i 35 E 6.35 (1/4") 9.53 (3/8") CL3000i 53 E 6.35 (1/4") 12.7 (1/2") CL3000i 70 E 9.53 (3/8") 15.9 (5/8") Table 3 Pipe diameter depending on appliance type Climate 3000i – 6721823680 (2021/02)
  • Page 5: Unit Installation

    We recommend extending the pipes before mounting the indoor unit. ▶ Thermally insulate the refrigerant pipes separately. ▶ Establish pipe connections as described in Chapter 3.4.1. ▶ Fit the insulation on the pipes and secure. Climate 3000i – 6721823680 (2021/02)
  • Page 6: Connecting Condensate Pipe To The Indoor Unit

    ▶ Secure cable to the strain relief [2] and connect to the terminals W, 1(L), 2(N), S and ▶ Note assignment of wires to the terminals. ▶ Reattach the covers. ▶ Route the cable to the outdoor unit. Climate 3000i – 6721823680 (2021/02)
  • Page 7: Connecting The Outdoor Unit

    • Protective conductor is properly attached • Connection cable is securely attached to the terminal strip All covers are fitted and secured. The horizontal louver of the indoor unit is fitted correctly and the actuator is engaged. Table 9 Climate 3000i – 6721823680 (2021/02)
  • Page 8: Troubleshooting

    Communication fault between main PCB of outdoor unit and main PCB of compressor drive −− Conflicting operating mode of indoor units; operating mode of indoor units and outdoor unit must correspond. 1) Leak detection not active if in a system with multi-split air conditioner. Table 10 Climate 3000i – 6721823680 (2021/02)
  • Page 9: Faults Without Indication

    ▶ Remove refrigerant with refrigerant recovery unit. Moisture or impurities in the refrigerant circuit. ▶ Evacuate refrigerant circuit. ▶ Fill with new refrigerant. Voltage fluctuations too high. ▶ Install voltage regulator. Defective compressor. ▶ Replace compressor. Table 11 Climate 3000i – 6721823680 (2021/02)
  • Page 10: Environmental Protection And Disposal

    Data Protection Officer, Information Security and Privacy (C/ISP), This symbol means that the product must not be disposed Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY. of with other waste, and instead must be taken to the waste...
  • Page 11: Technical Data

    Outdoor unit Air flow rate 1850 1850 2100 3700 Sound pressure level dB(A) Sound power level dB(A) Permissible ambient temperature °C –15...50/–15...24 –15...50/–15...24 –15...50/–15...24 –15...50/–15...24 (cooling/heating) Net weight/gross weight 23.5/25.4 23.7/25.5 33.5/36.1 43.9/46.9 Table 12 Climate 3000i – 6721823680 (2021/02)
  • Page 12 ≥ 1 2 0 ≥ 1 5 0 0010033858-002 ≥ 1 8 0 0 0010032598-001 A [mm] B [mm] C [mm] CL3000iU W 26 E CL3000iU W 35 E CL3000iU W 53 E CL3000iU W 70 E 1082 Climate 3000i – 6721823680 (2021/02)
  • Page 13 ≤ 6 m ≤ 6 m 0010034026-001 0010032602-001 0010032746-001 ØD ØD 0010032749-001 1. 1. 1. A [mm] B[mm] C[mm] D[mm] CL3000iU W 26 E CL3000iU W 35 E CL3000iU W 53 E CL3000iU W 70 E 0010032601-001 Climate 3000i – 6721823680 (2021/02)
  • Page 14 0010032752-001 0010032748-001 3. 3. 3. 3. 3. 3. 2. 2. 2. 2. 2. 2. 0010032754-001 0010032609-001 0010032747-001 0010032753-001 Climate 3000i – 6721823680 (2021/02)
  • Page 15 > 50 3. 3. 3. 2. 2. 2. 90° 0010032880-001 0010032750-001 2. 2. 2. 0010032751-001 0010032916-001 0010032913-001 0010032911-001 Climate 3000i – 6721823680 (2021/02)
  • Page 16 W 1(L) 2(N) S 230 V AC 0010032912-002 < 17 °C < 17 °C 0010032873-002 Climate 3000i – 6721823680 (2021/02)
  • Page 17 Bosch Thermotechnik GmbH Junkersstrasse 20-24 D-73249 Wernau www.bosch-thermotechnology.com...