B. General Operating Parts
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
OPERATION DURING
A POWER OUTAGE
SECTION 3.I
Figure 3.2 General Operating Parts
C. Fuel Specifi cations
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas or propane. Make sure the appliance is compatible
with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specifi ed
and approved parts.
D. Good Faith Wall Surface/TV Guidelines
These are good faith estimates of the temperatures of the
wall surface above the fi replace. Follow the installation
instructions and comply with all minimum clearances
to combustibles as specifi ed. Finishing materials that
comply with installation requirements can withstand these
temperatures. Wall surface temperatures could vary
depending on wall material and thickness. Refer to Figure
3.5 in regards to TV installation.
WARNING! Risk of Fire! Comply with all minimum
clearances to combustibles as specifi ed in the installation
instructions.
8
Heat & Glo • MEZZO36/ST, MEZZO48/ST, MEZZO60/ST, MEZZO72/ST Owner's Manual • 2300-971 Rev. P • 3/16
DECORATIVE DOORS
SECTION 4
GLASS ASSEMBLY
SECTION 4
CLEAR SPACE
SECTION 3.A.
155°F
170°F
12 in.
6 in.
Figure 3.3. Wall Surface Temperatures Above Appliance
(MEZZO36/MEZZO36ST/MEZZO48/MEZZO48ST)
155°F
190°F
245°F
12 in.
6 in.
TOP EDGE OF THE OPENING
APPLIANCE FRONT
Figure 3.4. Wall Surface Temperatures Above Appliance
(MEZZO60/MEZZO60ST/MEZZO72/MEZZO72ST)
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certifi cation. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.
TO CEILING
125°F
125°F
130°F
48 in.
42 in.
140°F
36 in.
145°F
30 in.
24 in.
18 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT
TO CEILING
125°F
125°F
135°F
48 in.
42 in.
140°F
36 in.
30 in.
24 in.
18 in.
MEASUREMENTS FROM