Troubleshooting
Before you contact an authorized specialist
Problem
Cause / Action
Unit is not
∙ Check the power supply / tem-
working
perature setting / ambient temper-
properly or
ature. ∙ Unblock the ventilation
at all
openings, install the unit freely.
Loading is
∙ Check the temperature setting /
too warm
ambient temperature. ∙ Open the
door only as long as necessary.
Loud noise
∙ Check the appliance position.
during opera-
∙ See the section "Operating
tion
noise".
Water on the
∙ Check the temperature setting.
unit bottom
Light does
∙ Check the power supply.
not work
∙ See "Changing the bulb".
Error codes
In the event of some malfunctions, the interior light
flashes when the appliance door is open:
LED flashes
Causes
1x
Temperature sensor failure
2x
Defrosting sensor failure
5x
Display communication failure
NOTE:
If a problem persists after following the steps above,
contact your trader or an authorized technician.
Technical Data
Climate class SN/N/ST/T: this appliance is intended
to be used at ambient temperature ranging from
10°C to 43°C.
Electrical connection............................................
Power voltage: .........................220-240 V~ / 50 Hz
Rated (defrost) power: ................................160 W
Rated current: ..............................................1.3 A
Dimension H x W x D / Weight...............................
Appliance size: ...................185.0 x 60.0 x 70.0* cm
*measured depth with door handle
Net weight: ..................................approx. 68.0 kg
For more information about the product, scan the QR
code on the supplied energy label and/or visit the
official website of the product data bank:
https://eprel.ec.europa.eu
The right to make technical and design modifications
during continuous product development remains
reserved.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.
25