MEASURING THE FLUE (Extension Flue Kits):
ONLY CUT EXTENDED FLUE LEN THS
► As with the Standard Flue measure from the
outside wall to the centre line of the flue tur ­
ret (length L).
► Subtract the usable length of the standard
flue (634 mm) from length L.
► Subtract the usable length of the turret
(52 mm) from length L.
► Subtract 960 mm for each full length exten ­
sion from the figure.
► Cut one of the extensions to the remainder.
► Cut both tubes square taking care not to distort
the tubes.
► Remove any burrs.
EXAMPLE:
Length L =
Subtract Standard Flue
Subtract Turret
Subtract Full Extension
Cut Length —
NOTE: Where extensions are reduced, cut
length which DOES NOT contain the seal.
ADDITION OF FLUE BENDS:
When flue bends are being used an allowance
of 94 mm per bend must be allowed from the
centre line of the bend. In the example shown
using a flue extension (960 mm) with 2 bends
will achieve a total length of 1148 mm.
FLUE INSTALLATION
2380 mm
— 634 mm
— 52 mm
— 960 mm
734 mm