STANDARD FLUE HORIZONTAL
MIN 250mm Ax1*
* Requires cutting
MAXIMUM FLUE HORIZONTAL
MAXIMUM FLUE VERTICAL START 4-1 BEND
MAXIMUM FLUE HORIZONTAL 4-1 BEND
Q j ........... L .. A
I ...............
H
B
c
Q
0100 - 5900 mm
Ax 1 4- B
74-C
1
x
x
0125-16500 mm
Ax 1 4- B x 17 4- Cx 1
FLUE OPTIONS 30CDÍ
MAXIMUM FLUE VERTICAL
START+2BENDS
e. n
i ii^ A
f
B I- ■■
■
'
1
0100-5900 mm
A x 1 + Cx 2+ Bx8
+ Fx1
0125-16500 mm
A x 1 4- C x 2 4- B x 18
4- F x 1
MAXIMUM FLUE VERTICAL
START 4- 3 BENDS
F
Q
B
EZZZ
C
O
0100 - 3900 mm
A x 1 4- C x 3
4- B x 7 4- Fx 1
0125-14500 mm
A x 1 4- C x 3
4- B x 17 4- Fx 1
MAXIMUM FLUE VERTICAL
WITH 2 X 45° BENDS
D
Q.
0100 - 7400 mm
(including terminal)
B x 8 4- D x 2 4- E x 1
0125-16500 mm
(including terminal)
B x 17 4- Dx 2 4- Ex 1
VERTICAL FLUE WITH
2 X 90° BENDS
E
B
I
.................. .1
C
(J
0100 - 5400 mm
(including terminal)
Bx74- Cx2 4-Ex1
0125- 14500 mm
(including terminal)
Bx 164- Cx 2 4-E
1
x
e 720 611 927-08.10
INSTALLATION & SERVICIN
INSTRUCTIONS FOR WORCESTER BOSCH
FLUE OPTIONS 30CDÍ
•
The diagrams (opposite) show the compo
nents used and the maximum flue length for
each configuration of 100 mm and
125 mm 0 flues.
•
Shaded flue components indicate the stan
dard 100 mm 0 horizontal flue.
•
Only straight flue sections can be reduced
in length and cut.
•
The flue terminal end can be fitted from the
inside or outside of the building.
•
Fixing kits are supplied with the flue exten
sion kits.
•
Horizontal 125 mm 0 and Vertical 100 mm
and 125 mm 0 flue kits are available with
separate instructions. Contact your supplier
or Worcester Bosch.
A
o .....
i ... i^ 7
B
I
■
.............
"•>
A - Standard horizontal flue (100 mm 0 shown)
B- Straight flue extension
C - Flue bend, 90°
D - Flue bends, 45°
E - Vertical terminal (vertical adaptor supplied
with terminal)
F - Vertical adaptor (used with horizontal
terminal)
Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Horizontal 60/100 mm 0: 7900 mm
Horizontal 80/125 mm 0: 18500 mm
Vertical 60/100 mm 0: 9400 mm
Vertical 80/125 mm 0: 18500 mm
Then reduce the total straight flue length for
each extra flue bend (excluding the turret) by:
2000 mm for 90°
1000 mm for 45°
Flue extension total lengths:
Horizontal & Vertical 60/100 mm 0: 960 mm
Horizontal & Vertical 80/125 mm 0:1000 mm
Flue terminal total lengths:
Horizontal 60/100 mm 0: 800 mm
Horizontal 80/125 mm 0: 1200 mm
Vertical 60/100 mm 0: 1140 mm
Vertical 80/125 mm 0: 1365 mm