Connection: gas and electrical

Directions for use of gas and gas connection
Check that installation or local distribution regulations (type of gas and gas pressure) match the setting value of this
device. The setting values of this device are indicated on the type plate.
This device is not equipped with a combustion gas drain installation.
Installation and connection must comply with the regulations in force locally and nationwide. You must check the
regulations in regards to ventilation requirements.
The gas connection must comply with the general regulations. We recommend to connect the hob with a fixed gas pipeline
or to use an approved gas hose.
Always use a full metal hose behind the oven.
An approved gas hose should not be kinked and should not come into contact with moving parts of the kitchen furniture.
The main gas supply must be in an easily accessible place.
Use a gas hose with a maximum length of two meters in the case of LPG (bottled gas).
Never fill an LP gas cylinder more than 80%.
Before using the cooking unit check all the connections for leaks with soapy water.
Do not store or use gas cylinders or other flammable vapors or liquids near the PITT
Electrical connection instructions*
The electrical installation must conform to the national and local regulations.
Power socket and plug must always be reachable.
Connect the unit with the supplied plug to an earthed socket.
Damage to the connection cable may only be replaced by the manufacturer, or an approved Installer. This to prevent
dangerous situations.
Battery spark ignition*
The spark ignition operates through a battery AA. Replace the battery if the spark ignition does not operate
The battery is positioned in the casing at the underside.
* Depending on the model
Overview Outdoor assortment
Model PITT Totaal kW Bel. gr/h
Akan
1,8 Kw Hs 130
Altar
3 kW Hs
Azuma
5 kW Hs
Air
5 kW Hs
EN
Baluran
8 kW Hs
Bennett
6,8 kW Hs 490
Baula
8 kW Hs
Bely
6,8 kW Hs 490
Capital
9,8 kW Hs 710
Cima
9,8 kW Hs 710
220
360
360
580
580
Gastype - nozzle combination overview
Gas
Supply
Burner
pressure
0,3 - 2 kW
nozzle
G25
25 mbar
1.02
G25.3
25 mbar
1.02
G25
20 mbar
1.07
G20
20 mbar
1.01
G30
30 mbar
0.66
G30
50 mbar
0.58
G31
30 mbar
0.70
G31
37 mbar
0.66
G31
50 mbar
0.62
Unit category
Gas
I2H/E/LL
I2L/I2EK
G20/25
G25/G25.3
Supply
20
25
pressure
mbar
mbar
Class of appliances: 3
16
cooking system.
®
230 V – 50 Hz – 0,6 VA
1,5V DC
Burner
Burner
Burner
0,3 - 3 kW
0,2 - 5 kW
0,2 - 5 kW
nozzle
outer ring
inner ring
nozzle
nozzle
1.32
2x 1.18
1x 0,71
1.32
2x 1.18
1x 0,71
1.45
2x 1.28
1x 0,74
1.29
2x 1.15
1x 0,70
0.87
2x 0.72
1x 0.46
0,79
2x 0.68
1x 0.40
0.94
2x 0.80
1x 0.48
0.87
2x 0.72
1x 0.46
0.80
2x 0.70
1x 0.42
I3+
I3B/P
G30/31
G30/31
30/37
50
mbar
mbar
I3P
G31
50