Standard screens appear when the display is powered on depending on what is setup:
Net Weight - set this in Display - Power On Screen (1).
Gross Weight - set this in Display - Power On Screen (2).
Time / Date - set up in Outputs - Set Time / Date. (3).
Axles (No. of and weight on each) - set in Setup - Vehicle Config - Weigh Mode - Axles.
Twin (No. of and weight on each) - set in Setup - Vehicle Config - Weigh Mode - twin/5+air.
Load / Deliver - set in Setup - Settings - Load / deliver.
Shown above are the three main standard screens
The standard screens available in Analogue mode are:
Net Weight - set this in Display - Power On Screen (1).
Gross Weight - set this in Display - Power On Screen 2).
Time / Date - set up in Outputs - Set Time / Date (3).
Load / Deliver - set in Setup - Settings - Load / deliver
NOTES:
If no gross weight to be shown set the Tare to zero. Ensure that Load Cells (Vehicle Config) is set to Auto mode, either CAN or
Analogue will also be shown on the same line depending on which mode you are using.
Obtain Tare weight, maximum load and (if using axle weighing) the maximum load on each axle, using weighbridge / weighpads.
With vehicle empty go to: Menu - Setup - Calibrate.
(4) by pressing the UP arrow button until the Time / Date screen can be seen, then pressing the LEFT arrow button to get the Menu screen. Press the DOWN arrow button to get Setup followed by the LEFT arrow button to open the Setup screen. Press the DOWN arrow button to go to Calibrate followed by the LEFT arrow button to open the screen. Zero will be highlighted. Press the LEFT arrow button The screen shows "Are you sure? Yes / No". Press Yes, (LEFT arrow button). screen shows "Zero OK"(5) then returns to the previous screen. Press Exit 3 times to go to the main screen.
Load vehicle to as near full load as possible (for instance 20000kg).
Go to Menu - Setup - Calibrate. (see Zero Tare for how to do this). Go to Span with the DOWN arrow button and then press the LEFT arrow button.
Screen shows "Net Span Weight" and "Calibrate". Net Span Weight should be selected (6).
To alter weight press LEFT arrow button, first figure will be highlighted. Alter figure using Up / Down arrow buttons to alter values and LEFT arrow button to move along figure until correct value is reached (in this instance 20000kg) (7).
Press Exit to go to the previous screen. Press the DOWN arrow button to go to the "Calibrate" option followed by the LEFT arrow button. The screen will say "Are you sure? Yes / No". Press Yes (LEFT arrow button), screen shows "Zero OK"
Press Exit 3 times to go to the main screen.
Go to Menu - Setup - Alarms by pressing the UP arrow button until the Time / Date screen can be seen, then pressing the LEFT arrow button to get the Menu screen.
Press the DOWN arrow button to get Setup followed by the LEFT arrow button to open the Setup screen. Alarms should be highlighted. Press the LEFT arrow button to open the screen. Ensure that the Alarm Mode is set to Auto (8). If not press the LEFT arrow button. Press the DOWN arrow button and set the Net alarm weight to whatever is required.
To alter weight press Select button, first figure will be highlighted. Alter figure using Up / Down buttons to alter values and Select button to move along figure until correct value is reached. The Body Up alarm can be left unchanged.
The various screens are accessed by using the display buttons:
The ON / OFF button This is on the left of the display and is used to power up or power down the display. | ![]() |
The Left Arrow button This button is used to return to a previous screen or to edit a number. | ![]() |
The Up Arrow button This button is used to scroll up an on-screen list, or increment a number. | ![]() |
The Down Arrow button This button is used to scroll down an on-screen list, or decrement a number. | ![]() |
The Accept / Exit button This square button is used to accept changes to screens or parameters and exit the screen. Can also be used as the NO button. | ![]() |
Can be accessed from Menu - Setup - Reset Defaults
Display
Contrast: 5
Power On screen: Net weight
Key bleep: off
Alarms
Mode: manual
Net weight: 50 000kg
Gross weight: 50 000kg
Body up threshold: -500kg
Vehicle Config
Load cells: CAN
Weigh mode: standard
Tare weight: 5000kg
Cell P.I. value: 16384
Settings
Count by: 20kg
Filter: low
Zero Limit: 500kg
Front panel zero: On
Load deliver: Off
Language: English
Outputs Printer
Baud rate: 9600
Handshaking: Off
Print header: On
Remote channel: A
Auxillary output 1: Off
Auxillary output 2: Off
Set time / date
Daylight saving: On
Pin access
Pin control: Off
User alarms: No
Password
0000 (four zeros)
For any service requirements contact:
Vishay PM Onboard
+44 (0) 1274 822999
or
service@pmonboard.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the PM 1155 and is the answer not in the manual?
Questions and answers