Note
An earth ground connection does not connect C
© National Instruments Corporation
Figure 2-4 shows the power connector on the NI CVS-1450 device.
Table 2-2 lists and describes each terminal on the power connector.
POWER
C
iso
V
iso
(5-30 VDC)
C
V
(24 VDC ±10%)
Table 2-2. Power Connector Terminals
Terminal
V
C
V
iso
C
iso

Earth Ground Connection

Some system setups may require using the grounding lug on the
NI CVS-1450 device to connect the chassis to earth ground. Connecting
the grounding lug, shown in Figure 2-5, to earth ground connects the
common-mode signal of the main power to earth ground through the
NI CVS-1450 device chassis.
Chapter 2
POWER
C
iso
V
iso
(5-30 VDC)
C
V
(24 VDC ±10%)
Figure 2-4. Power Connector
Main power (24 VDC ±10%)
Common-mode signal
Isolated power (5 to 30 VDC)
Isolated common-mode signal
to earth ground.
iso
2-7
LEDs, DIP Switches, and Connectors
Description
NI CVS-1450 Series User Manual