Summary of Contents for National Instruments NI CVS-1450 Series

  • Page 1 CVS-1454...
  • Page 2: What You Need To Get Started

    Software for developing applications: – LabVIEW – LabVIEW Real-Time Module – NI Vision Development Module Optional Equipment National Instruments offers a variety of products for use with the NI CVS-1450 device, including the following: • DCAM-compliant IEEE 1394 cameras • Camera lenses...
  • Page 3: Related Documentation

    • 75 Ω SMB 111 coaxial cable (part number 763422-01)—SMB to BNC cable for connecting to triggers and light sources Visit or call the National Instruments office nearest you for more information about these ni.com products. Related Documentation The following documents contain additional information that you may find helpful: •...
  • Page 4 Remove power from signal lines before connection to or disconnection from the device. Caution National Instruments measurement products may be classified as either Measurement Category I or II. Operate products at or below the Measurement Category level specified in the hardware specifications.
  • Page 5: Hardware Installation

    If your camera requires an external power supply, connect it to the camera, and verify that the camera is powered on. Note To maintain signal integrity, the IEEE 1394 cable length must be no longer than 4.5 m. Plug in and power on the monitor. Getting Started with the NI CVS-1450 Series ni.com...
  • Page 6 Connecting the NI CVS-1450 Device to a Network section. If the images from the camera are not displayed on the monitor, refer to the NI CVS-1450 Series User Manual for troubleshooting information. © National Instruments Corporation Getting Started with the NI CVS-1450 Series...
  • Page 7 Do not connect the NI CVS-1450 device main power to a source other than 24 VDC ±10%. Do not connect the NI CVS-1450 device isolated power to a source less than 5 VDC or greater than 30 VDC. Doing so could damage the NI CVS-1450 device. Getting Started with the NI CVS-1450 Series ni.com...
  • Page 8 To prevent data loss and to maintain the integrity of your Ethernet installation, do not use a cable longer than 100 m. If you are using a 100 Mbps Ethernet, National Instruments recommends using a CAT 5 or CAT 6 shielded twisted-pair Ethernet cable.
  • Page 9: Software Installation

    When the installation screen appears, click Install LabVIEW, and follow the setup instructions. Insert the LabVIEW Real-Time Module CD into the CD-ROM drive. When the installation screen appears, click Install LabVIEW Real-Time Module, and follow the setup instructions. Getting Started with the NI CVS-1450 Series ni.com...
  • Page 10 Review your selection in the Summary window. Use the Back button to modify your software settings if needed. Click Next. Once the software is installed, the NI CVS-1450 device will automatically restart. Click Finish when this process is completed. © National Instruments Corporation Getting Started with the NI CVS-1450 Series...
  • Page 11: Acquiring An Image

    Click the Snap button to acquire a single image, or click the Grab button to acquire continuous images. Now that you are acquiring images, you can use the NI Vision Development Module and the installed NI CVS-1450 device drivers to process images and control inputs and outputs. Getting Started with the NI CVS-1450 Series ni.com...
  • Page 12: Specifications

    Do not draw more than 500 mA combined from the Viso pins on the 44-pin DSUB connector. Do not draw more than 100 mA from 24V or 30V isolated outputs. Do not draw more than 50 mA from 5V isolated outputs. © National Instruments Corporation Getting Started with the NI CVS-1450 Series...
  • Page 13 ..............50 mA, maximum 24 V ............100 mA, maximum 30 V ............100 mA, maximum Maximum pulse rate ..........10 kHz (maximum load resistance 100 kΩ) Minimum pulse generated ........100 µs Reverse polarity protection ........Yes Getting Started with the NI CVS-1450 Series ni.com...
  • Page 14: Physical Characteristics

    Dimensions ............10.2 cm × 12.7 cm × 6.4 cm (4 in. × 5 in. × 2.5 in.) Weight ..............1 kg (2.2 lb) Refer to Appendix B, Mounting Information, of the NI CVS-1450 Series User Manual for dimensional drawings of the NI CVS-1450 device. Environmental The NI CVS-1450 device is intended for indoor use only.
  • Page 15: Electromagnetic Compatibility

    Certification column. Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the environment but also to NI customers.
  • Page 16: Where To Go For Support

    National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 8248.
  • Page 17 Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents.