APPENDIX B: BOOT STATUS CODES (RUN_STATUS)

The following table describes the Boot status codes returned by the startup processes accessible
though the GET_RUN_STATUS control utility command.
CODE
LABEL
0
INIT
1
DATA_PARTITION_NOT_FOUND
2
FACTORY_DATA_SUCCESS
3
UPGRADE_DATA_SUCCESS
4
FACTORY_DATA_IN_PROGRESS
5
UPGRADE_DATA_IN_PROGRESS
6
DFU_IN_PROGRESS
7
HW_BUILD_READ_SUCCESS
8
HW_BUILD_PARTITION_SIZE_ERROR
9
HW_BUILD_PARTITION_BASE_ERROR
10
HW_BUILD_READ_ERROR
11
HW_BUILD_CRC_ERROR
12
HW_BUILD_TAG_ERROR
13
FACTORY_VERSION_ERROR
14
UPGRADE_VERSION_ERROR
15
FACTORY_ITEM_READ_ERROR
16
UPGRADE_ITEM_READ_ERROR
17
FACTORY_ITEM_INVALID_TYPE
18
UPGRADE_ITEM_INVALID_TYPE
19
DFU_FLASH_CONNECT_FAILED
20
DFU_FLASH_SPEC_UNSUITABLE
XM-014232-PC
NOTE
Reserved initial value. Decline attempts to initiate DFU.
Not used.
Normal operation.
Normal operation.
Image scanning in progress. Decline attempts to initiate DFU.
Image scanning in progress. Decline attempts to initiate DFU.
Enough DFU commands received to establish a connection to on-board flash
memory. Not cleared until reboot.
Reserved intermediate value. Normally never returned.
Problem reading data partition header. Check factory programming.
Problem reading data partition header. Check factory programming.
Problem reading data partition header. Check factory programming.
Problem reading data partition header. Check factory programming. May indicate
that no data partition is present or a flash wear issue.
Problem reading data partition header. Check factory programming.
No valid upgrade image found. A factory image did not match running version. This
can indicate fail-safe mode.
Valid upgrade boot and data images found but data image version does not match
running version. Check correct version of deployed field upgrade.
Problem reading configuration items from data image. Unexpected error.
Problem reading configuration items from data image. Unexpected error.
Last item encountered is not of terminator type. Should never happen with script
generated data images. Check generation procedure.
Last item encountered is not of terminator type. Should never happen with script
generated data images. Check generation procedure.
Failed to establish on-board flash connection. Check factory programming. Check
flash specification (see section below).
Flash specification unsuitable for DFU. Check flash specification (see section
below).