2. Remove the female JIC #4 cap from the male JIC #4 adapter and attach the pressure
gauge to the hydraulic control valve (see illustration below).
SWL P/N: 10P37
Hydraulic Adapter
MP/MJIC 90° (-4-4)
PRESSURE GAUGE TO HYDRAULIC ADAPTER ILLUSTRATION
3. Start the truck and engage the P.T.O.
4. Push the lift (dump) circuit lever forward until the lift (dump) cylinders bottom out (see
illustration below). Continue to push the lever forward until steps 5-6 are complete.
5. Check the gauge for the maximum developed system pressure. The SL-400 should have
a reading of 3,500 PSI.
6. With the pressure check complete; release all functions and disengage the P.T.O.
Please contact your SwapLoader Distributor or SwapLoader USA should you have any
questions regarding this procedure.
SL-400.MAI
07/2009
Hyd Control Valve Ass'y
FRONT
LOWER/LOAD
EXTEND
LIFT
JIB
RAISE/UNLOAD
RETRACT
2500
2000
3000
1500
3500
1000
4000
500
4500
0
5000