1.
Install the hydraulic pump to the P.T.O. (Bolts are not provided).
2.
Install the hydraulic fittings into ports on the hydraulic pump as shown on Drawing No.
91H04.
3.
Connect the suction hose assembly to the hydraulic tank (1 1/2" I.D. hose) and route to
the hydraulic pump in as short and straight line as possible. Be sure to route the hose
clear of exhaust components and of the drive shaft. Extra hose is provided so the hose
can be shortened to an appropriate length. Install the hose on the hose barb fittings at the
tank and at the pump and secure with the hose clamps provided.
NOTE: Prior to startup, this hose must be filled with oil.
4.
The pressure hose from the hydraulic pump to the control valve assembly is not supplied
with the hoist as it must be made to the proper length. This hose must be purchased from
a local hydraulic hose assembly supplier per the following specifications:
Hose I.D.:
Working Pressure:
Hose Fitting Threads:
5.
Install the pressure hose as indicated. Tie up the pressure and suction hoses as necessary.
Again, be sure the hoses are routed to avoid exhaust components and to stay clear of the
drive shaft.
SL-400.INS
09/2009

PUMP INSTALLATION

3/4 inch
3500 PSI
SAE 37° (JIC) 1 1/16-12