Page 2
[02] x 1 [03] x 1 [01] x 1 [05] x 4 [06] x 1 [04] x 1 [08] x 4 [09] x 4 [07] x 1 [11] x 4 [12] x 4 [10] x 1 (6x70mm) (6.3x17x2mm) [13] x 8 (4x12x1mm) [14] x 4 [15] x 4...
Let's get started... These instructions are for your safety. Please read through them thoroughly before use and retain them for future reference. Getting started... Safety Before you start more detail... Product functions Switching on/off Care and maintenance Troubleshooting Recycling and disposal Technical and legal information CE Declaration of conformity Appendix...
Safety These instructions are for your safety. Please read through them thoroughly prior to installation and retain them for future reference. • All installation work must be carried out by a competent person or qualified electrician. • This appliance must be installed correctly by a suitably qualified person, strictly following the manufacturer’s instructions.
Page 5
Safety not be made by children unless they are older than 8 and supervised. Keep the appliance and its cord out of reach of children less than 8 years. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
Page 6
Safety Do not use flammable sprays in close vicinity to the appliance. We also recommend that great care be taken during use and cleaning. Read the cleaning and maintenance sections for this appliance carefully. A steam cleaner is not to be used. The appliance is not intended to be operated by means of external timer or separated remote-control system.
Page 7
Safety involves no risk of damage. Switch off the electricity supply to the hood and reconnect after one minute. To avoid the risk of fire, clean the metal filter regularly and closely watch and regulate pans containing hot oil. Do not use the hood if it shows signs of damage or imperfection.
Before you start Your product Installation guide located at the end of the guidebook Things to check before you start To avoid the risks that are always present when you use an electrical appliance it is important that this cooker hood is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards.
Operation Product functions • This appliance extracts the air of the kitchen to remove the odours and keep an optimum level of air quality inside the room, it also allows you to illuminate the cooking area. Switching on/off • Switch on the appliance at the switched fused connection unit. The appliance is ready for use.
Care and maintenance Care and maintenance Warning Always switch off the electricity supply before carrying out maintenance work on the hood. In the event of a FUSE fault, contact customer services. Bulb replacement DOUBLE POLE SWITCHED FUSED SPUR OUTLET FUSE ON 10’...
Page 12
Care and maintenance Active charcoal filter replacement 2 X ACTIVE CHARCOAL FILTER (NOT SUPPLIED). MODEL NUMBER CARBFILT2 (UK & IE) CARBON FILTER ORDERING HOTLINE 0344 800 1128 (UK) 014475261 (IE)
Page 13
Care and maintenance Aluminium and active charcoal filters replacement 1 MONTH MAX.65˚C Aluminium filters: To avoid fires, clean thoroughly once a month or whenever the display pilot light lights up (if fitted). To do so, remove the filters and soak in hot water and detergent for an hour.
Troubleshooting Troubleshooting Fault Cause Solution Excessive The appliance is not Take down the appliance and vibration. installed properly on the check it is properly fixed. brackets. The fan blade is Switch off the appliance. Repair damaged. to be carried out by qualified service personnel only.
Recycling and disposal Technical and legal information Recycling and disposal Environmental protection Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice. The symbol on the product or its packaging indicates that this product cannot be treated as normal household waste.
Page 16
Technical and legal information Wiring All installation work must be carried out by a competent person or qualified electrician. Before connecting the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate. WARNING: THIS APPLIANCE MUST NOT BE EARTHED. Mains Supply could be connected to the Mains Voltage by Direct Connection DOUBLE POLE SWITCHED FUSED SPUR OUTLET...
Page 17
Technical and legal information Technical and legal information The Manufacturer declines all liability for damage caused to persons and objects due to incorrect or improper installation of the appliance. Electrical Requirements Any permanent electrical installation must comply with the latest I.E.E. regulations and local electricity company regulations.
We hereby certify that the mentioned accessory complies with the essential requirements of the European Directives applicable, including their modifications and the corresponding transpositions from the national law. MACHINE APPLICATION: GIHD90SS Decorative Cooker Hood TYPE: Comply with the European Directives 2006/95/EC: LVD...
Installation CARBFILT2 (UK & IE) or CARBFILT2CL (FR) VENT PACK 2 (UK + IE) Φ125mm or Φ150mm DUCTED OPTION RECIRCULATION OPTION You can choose two type of installation: - Ducted option - Recirculation option Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards DIM.B...
Page 20
Ø4mm Front Ø10mm [17] x 4 Mark and drill four holes of 4 mm diameter on the ceiling according to the dimensions shown. Remark: For cement ceiling, drill four holes of 10mm diameter then insert the plugs. [13] [19] [19] x 8 [13] x 8 Fix the upper and lower part of bracket together at the required length using eight sets of screws and washers.
Page 21
Installation [08] x 4 [09] x 4 [18] x 4 [10] x 1 Insert the 4x bolts, rubber washer and washer and tighten with the allen key, ensuring not to over tighten as this may cause damae to the glass. [19] [07] x 1 [07]...
Page 22
Vent Pack 2 (UK + IE) Fix the vent pack 2 using self adhesive aluminium tape. [11] x 4 [12] [11] [12] x 4 Hold up the hood and fix it onto the ceiling using four sets of long screws and washers.
Page 23
[03] x 1 Place the lower chimney and upper chimney as shown.Then use a screwdriver to insert one hole for fixing chimney. [14] x 4 [14] [15] [16] [15] x 4 [16] x 4 Fix the bracket onto the hood body using four sets of nuts, safety washers and washers.
Page 24
a.10 Fix the vent pack 2 using self adhesive aluminium tape. a.11 Take out the screwdriver, let these chimney to drop down as shown.
Page 25
Vent Pack 2 (UK + IE) Fix the vent pack 2 using self adhesive aluminium tape. [14] x 4 [14] [15] [15] x 4 [16] [16] x 4 Fix the bracket onto the hood body using four sets of nuts, safety washers and washers.
Page 26
[03] x 1 Place the lower chimney and upper chimney as shown. [12] [11] x 4 [11] [12] x 4 Hold up the hood and fix it onto the ceiling using four sets of long screws and washers.
Page 27
b.10 Fix the vent pack 2 using self adhesive aluminium tape. [19] x 2 [19] Pull out the upper chimney and fix it onto the bracket using two screws.
Page 28
[06] x 1 Remove the aluminium filter. [19] x 2 [19] Fix the lower chimney using two screws.
Page 29
[06] x 1 Replace the aluminium filter. Remove the protective film, for Stainless Steel only. For recirculating option refer to Care and maintenance section. Note: For electrical connection see Technical and legal information section.
Appendix... Information for EU66 (A)Information of the cooker Hood (www.diy.com) Symbol Value Unit Model identification GIHD90SS Annual Energy Consumption 238.6 kWh/a hood Time increase factor Fluid Dynamic Efficiency 17.5 hood Energy Efficiency Index 105.1 hood Measured air flow rate at best 383.6...
Page 32
Apelson Appliances UK Limited Unit 3 Normandy Landings Pope St Castleford WF6 2AG...
Need help?
Do you have a question about the GIHD90SS and is the answer not in the manual?
Questions and answers