Pulse counters, electronic
LCD pulse counters
Accessories
Adapter front bezel, 72 x 36 [2.83 x 1.42]
Adapter front bezel, 48 x 48 [1.89 x 1.89]
Adapter front bezel, 60 x 50 [2.36 x 1.97]
Transparent cover, lockable, IP65
Sealing cover type K1, IP65
Mounting frame
with cut-out 50 x 25 [2.36 x 1.97]
via separate adapter also for 45 x 22.2 [1.77 x 0.87]
Suitable gaskets as well as further accessories can be found in the accessories section or in the accessories area of our website at: www.kuebler.com/accessories.
Technical data
General technical data
Display
Backlighting
Modes
Display range
Reset
Working temperature
Operating temperature
Storage temperature
Altitude
Electrical characteristics
Power supply
EMC
Emitted interference
Immunity to interference
Designed to
Device safety
Protection class
Application area
UL approval
Mechanical characteristics
Housing
Protection
Weight
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
With count direction AC (battery)
Dimensions in mm [inch]
For cut-out 68 x 33 [2.68 x 1.30] to cut-out 45 x 22.2 [1.77 x 0.87],
for counters 48 x 24 [1.89 x 0.94], as set
For cut-out 45 x 45 [1.77 x 1.77] to cut-out 45 x 22.2 [1.77 x 0.87],
with clip mounting for counters 48 x 24 [1.89 x 0.94]
For cut-out 54 x 29 [2.13 x 1.14] to cut-out 45 x 22.2 [1.77 x 0.87],
with screw mounting and gasket for counters 48 x 24 [1.89 x 0.94]
For cut-out 54 x 29 [2.13 x 1.14], for screw mounting to front bezel F1B or
adapter front bezel N003001,
for counters with cut-out 50 x 25 [1.97 x 0.98] or 45 x 22.2 [1.77 x 0.87]
Suitable for front bezel 60 x 50 [2.36 x 1.97], for screw mounting of electromech.
counters and via adapter front bezel N003001 for counters 48 x 24 [1.89 x 0.94]
For snap-on mounting on 35 [1.38] top-hat DIN rail,
for counters 53 x 28 [2.09 x 1.10]
and via separate adapter (T008180) for counters 48 x 24 [1.89 x 0.94]
LCD, 8 digits, 8 mm [0.32"] high
external electrical source
24 V DC ±20 %, 50 mA
counting direction (count
and direction input)
-9999999 ... 99999999,
with overflow display
manual and electrical
-10°C ... +55°C [+14°F ... +131°F]
(non-condensing)
-10°C ... +60°C [+14°F ... +140°F]
(non-condensing)
-20°C ... +70°C [-4°F ... +158°F]
up to 2000 m [6562']
internal lithium battery
approx. 8 years at 20°C [68°F]
EN 55011 class B
EN 61000-6-2
EN 61010 part 1
2
Pollution level 2
File-No.: E128604
dark grey RAL 7021
IP65 (front side)
approx. 50 g [1.76 oz]
black and silver anodised
Counting inputs
Counting input of the high voltage versions (10 ... 260 V DC/AC)
Counting and direction input
Optocoupler input
Minimum pulse time
Switching level
Reset input
Minimum pulse time
High voltage
Contact input DC – NPN
Electrical reset key locking
Contact input
Switching level – NPN
Terminal assignment
AC type: 6.132.012.8x3
BL = backlighting
Codix 132
Order-No.
162704 Set
T008883
black
N003001
black
N003002
G008301
G300004
chromated
max. 30 Hz
16 ms
LOW
0 ... 2 V AC/DC
HIGH
10 ... 260 V AC/DC
DC
50 ms
16 ms
LOW
0 ... 0.7 VDC
HIGH
3 ... 30 V DC
open collector NPN
(switching at 0 V)
LOW
0 ... 0.7 V DC
HIGH
3 ... 5 V DC
max. 5 V DC
max. 5 V DC
INP A
INP A
1
1
10 .. 260
10 .. 260
VAC/VDC
VAC/VDC
Common
Common
2
2
AC/DC
AC/DC
10 .. 260
10 .. 260
VAC/VDC
VAC/VDC
INP B
INP B
3
3
Reset
Reset
4
4
Enable
Enable
Reset
Reset
5
5
GND
GND
6
6
(-) BL
(-) BL
7
7
24 V DC ±20 %, 50 mA
24 V DC ±20 %, 50 mA
(+) BL
(+) BL
8
8
Need help?
Do you have a question about the Codix 132 and is the answer not in the manual?