Turbo Air Jumbo TJMR-30SD N Series Installation And Operation Manual page 17

Glass door merchandisers refrigerators and freezers and ice merchandisers
Table of Contents

Advertisement

TROUBLESHOOTING
SYMPTOMS
Cooler is freezing
food.
The unit does not
refrigerate at all.
The unit does not
refrigerate well.
There is a loud
noise.
There are dew-
drops on the unit
exterior.
There are dew-
drops on the unit
interior.
The door does
not close tightly.
The following points are not malfunctions:
• A water-flowing sound can be heard when the compressor stops.
This is the sound of REFRIGERANT flowing.
• The compressor does not run during the defrost cycle.
Note: Formation of condensation on and around the edge of the door and the front
side of the cabinet is normal. Gurgling noises inside the refrigerating circuit are normal.
CAUSES
• Thermostat set too cold.
• There is a power connection
failure problem.
• The unit is in sunlight or near a
heating device.
• The unit contains hot food or
too much food.
• The unit door is opened too
frequently or left open long.
• The temp. dial is not on the
correct position.
• The condenser is clogged.
• The floor is too weak or the
leveling feet is set incorrectly.
• The back-side of the unit is too
close to the wall.
• High-moisture air can produce
dewdrops during rainy season.
• The door is opened too
frequently or left open long.
• Damp food is stored.
• The door is bent.
• The unit is a levelling failure.
• The door gasket has come out.
17
Turbo air
SOLUTIONS
• Turn the thermostat
setting to a higher
temperature position.
• Check the power cord
and plug in correctly.
• Check the installation
place.
• Check the condition of
stored food.
• Check the position of
the temp control dial.
• Check the installation.
• Wipe with a dry cloth.
• Keep the door closed
to remove dewdrops.
• Level the unit again.
• Reposition the gasket.