3. Specifications

3.1
Models covered by these instructions:
Micro Charger Model 9713V (V-Mount).
Micro Charger Model 9713 (Gold Mount).
3.2
Range of Batteries Charged:
Model 9713V is designed for charging the following V-Mount Li-Ion
batteries, individually or linked:
• PAGlink & Mini PAGlink
• PAG L90 Slim
• PAG L95e, L96e & L96T
• Sony V-Mount Li-Ion
Model 9713 is designed for charging the following Gold Mount Li-Ion
batteries, individually or linked:
• PAGlink & Mini PAGlink
• PAG L95e, L96e & L96T
3.3
Charging Multiple PAGlink Batteries:
PAGlink allows up to 8 batteries to be linked for charging, and Mini
PAGlink allows up to 10. However, the maximum number of fully-
discharged batteries that can be fully-charged in a 12 to 16 hour
period, using the Micro Charger, is as follows:
50Wh batteries
8
94-99Wh batteries
4
150Wh batteries
2
Any mix of Gold Mount PAGlink & Mini PAGlink batteries can be linked
for charging. The batteries can be in any state of charge. Any mix of
V-Mount PAGlink batteries, and any mix of V-Mount Mini PAGlink
batteries can also be linked for charging, but V-Mount PAGlink and
Mini PAGlink batteries cannot be linked to each other.
3.4
Main Charge Program:
Li-Ion voltage-charge program.
3.5
Recovery Charge:
This special program will automatically recover a PAG Li-Ion battery
where the output has been shut down.
3.6
Self Test Program:
The internal microprocessor constantly monitors the battery under
charge as well as the operation of the charger's own functions which
will be shut down to a safe condition should any of the tests fail.
3.7
Input:
Charger: DC 5-20V. Connector: 2.1mm DC, any polarity. Power Supply
Unit: AC 100-240V ~ autoselected. Frequency 50-60 Hz. Maximum
power consumption 35W.
3.8
Output Protection:
Protected against short circuit and open circuit.
3.9
Power Input Failure Protection:
Should power failure occur during a charging program, or whilst the
charger is connected, it will shut down to a safe condition.