CONTROL UNIT CALIBRATION
If for any reason the controls should stop responding the unit will need to be calibrated; the
procedure for this is shown below.
With the unit powered off; simultaneously press
and hold both rotor direction buttons before then
powering on the unit.
Press and release the rotor stop button to enter
calibration mode; all led's will simultaneously flash
once to confirm.
Operate the joystick through its complete range of
movements 4 to 5 times then operate each toggle
switch fully forwards and fully backwards 4 to 5 times.
When all the led's light up; release both buttons.
Power led will flash on and off continuously
whilst the unit is in calibration mode.
Press the rotor stop button once to exit calibration
mode; the rotor stop led will flash rapidly to confirm
and the power led will stop flashing and remain lit.
44