86
87
89
terminal 50
key switch
battery
90
25 LD 330-2_425-2 Workshop Manual_cod. ED0053031690_1° ed_ rev. 00
88
blue
red
key switch
terminal 15/54

Injectors and injector pipes

Mount injectors to heads placing copper gaskets in between
(see pag. 36).
Connect the injectors to the pumps by way of the injection lines.
Important
• Important: always use two wrenches to loosen or tighten the
unions on the injector pipes (fig.86) thereby ensuring that the
position of the delivery valve holder on the pumps is not changed
(see pag.33).

Oil filter

Fit the mesh type oil filter cartridge into the crankcase (fig.87)
and check that the rubber seals and the O-ring on the cover are
in good condition.
On request 25LD425-2 engines can mount an external filter
cartridge that can be screwed onto the crankcase (fig.88). Oil
the seal before assembly.

Feed pump

1. Insert the fuel feed pump tappet into its housing and make
sure that it moves freely.
2. Fit the 0.2 and 1mm adjustment gaskets.
3. With the fuel pump excenter in rest position the tappet
should protrude from the gasket surface (fig. 89) by:
4. With the fuel feed pump cam in the rest position mount the
pump and actuate it manually .

Electric shut off

If the engine is equipped with an electric shut off, insert the
electro-magnet into the crankcase taking care to position the
engine shut-off lever in the STOP position; make sure that the
injection pump connection lever moves freely along its entire
stroke.
Make the electrical connections as shown in diagram 90.
1,3 ÷ 1,7 mm
7
- 47 -