Green FADING—The controller has entered the standby (S3) state.
OFF—The controller is powered off.
Red BLINKING—The controller detected a power rail fault when trying to
boot.
Red SOLID—The controller detected a thermal fault and has shut down to
protect the system.
USER LEDs — Two bi-color green/yellow LEDs (USER1 and USER2) that you
can define to meet the needs of your LabVIEW application.

Removing the PXIe-8861 from a PXI Express Chassis

To remove the PXIe-8861 from a PXI Express chassis, complete the following steps.
1. Power off the chassis.
2. Remove any cables that may be attached to the controller front panel.
3. Unscrew the four bracket-retaining screws in the front panel.
4. Press the injector/ejector handle down.
5. Slide the unit out of the chassis.
Note
If the PXI Express chassis Inhibit Mode Selector Switch is not in the
Default position, any attempt to shut down the PXIe-8861 through the
push button reset or using Windows will result in the controller Power OK
LED blinking. The user must use the Remote Inhibit pin on the Remote
Inhibit and Voltage Monitoring Connector to turn off the chassis. Refer to
the PXI Express chassis user manual for details on the functionality of the
Remote Inhibit and Voltage Monitoring controls. For chassis without a
Remote Inhibit pin, turn off the chassis AC power.
Installing the Removable Hard Drive (Removable Hard Drive Variant
Only)
To install the removable hard drive, complete the following steps:
PXIe-8861 Getting Started Guide
© National Instruments
9