Password = 59 » Display Scrolling Time
P A S
Enter Password = 19
1 9
Press
Key
SET
p O N
Power on
T I M
Time
5
(0-99 Sec)
Press
Key
SET
I T D
Initial Delay
T I M
Time
5
(0-99 sec)
Press
Key
SET
U N C
Under Current
E N B
(Enable/Disable)
Press
Key
SET
If Enable
U N C
Under Current
V A L
Value
If
2 0 0
(0.00-CTR)
Disable
Press
Key
SET
U N C
Under Current
T I M
Delay Time
5
(0-999 Sec)
Press
Key
SET
O V C
Over Current
E N B
(Enable/Disable)
Press
Key
SET
If Enable
O V C
Over Current
V A L
Value
5 0 0
(0.00-CTR)
Press
Key
SET
O V C
Over Current
T R P
Trip on
T I M
( Time/Curve )
Press
Key
If
If
SET
Curve
Time
O V C
O V C
Over Current
Over Current
T I M
C R V
Delay Time
Curve Value
5
(0-999 Sec)
5 0 C
(2.5C/5.0C/
Press
Key
SET
O V V
Over Voltage
E N B
(Enable/Disable)
Press
Key
SET
If Enable
O V V
Over Voltage
v A L
Value
4 8 0
(50-550V for 3Ø3W)
Press
Key
SET
(30-330V for 3Ø4W)
If
O V V
Over Voltage
Disable
t I M
Delay Time
5
(0-999 sec)
Press
Key
SET
U N V
Under Voltage
E N B
(Enable/Disable)
Press
Key
SET
If Enable
U N V
Under Voltage
V A L
Value
If
3 8 0
(50-520V for 3Ø3W)
Disable
(30-300V for 3Ø4W)
Press
Key
SET
U N V
Under Voltage
T I M
Delay Time
5
(0-999 Sec)
Press
Key
SET
U F
Under Frequency
E N B
Enable / Disable
Press
Key
SET
If Enable
U F
Under Frequency
V A L
Value
4 5 0
(45.0 to 65.0Hz)
If
Disable
Press
Key
SET
U F
Under Frequency
T I M
Delay time
5
(0 to 999 sec)
Press
Key
SET
O F
Over Frequency
E N B
(Enable / Disable)
Press
Key
SET
If Enable
O F
Over Frequency
V A L
Value
5 5 0
(45.0 to 65.0Hz)
If
Disable
Press
Key
SET
O f
Over Frequency
T I M
Value
5
(0 to 999 sec)
Press
Key
SET
Press
key to Save & exit
SET
Password = 29 » Single Phase Prevention (SPP)
Short Circuit, Lock Rotor Point,
Unbalance Current, Phase Sequence,
Phase Loss
Long Press
Key to enter into Password
SET
SET
P A S
P A S
Press
Key
SET
S P P
E N B
Press
Key
SET
S P P
T R P
V L T
Press
Key
SET
S P P
If
Disable
T I M
Press
Key
SET
E N B
Press
Key
SET
If
S C L
Disable
Press
Key
SET
L R P
E N B
Press
Key
SET
L R P
10C )
If
S C L
Disable
Press
Key
SET
u n b
e n b
Press
Key
SET
u n b
P E R
If
Disable
Press
Key
SET
u n b
t I m
Press
Key
SET
p h a
L O s
E N B
Press
Key
SET
p h a
S E Q
E N B
Press
»
PARAMETER SETTING
Enter Password = 29
Enter Password = 29
2 9
2 9
Single Phase Prevention
(Enable / Disable)
If Enable
Single Phase Prevention
Trip On
( Voltage/Current )
Single Phase Prevention
Time
(0 to 999 Sec )
5
S C
Short Circuit
(Enable / Disable)
If Enable
S C
Short Circuit
Scale
2
( 1-9 )
Lock Rotor Point
(Enable / Disable)
If Enable
Lock Rotor Point
Scale
2 0
( 0.5 - 9.0 )
Un Balance
(Enable / Disable)
If Enable
Un Balance
Percentage
2 0
( 5-60% )
Un Balance
Delay Time
5
( 0-999 Sec )
Phase
Loss
(Enable / Disable)
Phase
Sequence
(Enable / Disable)
key to Save & exit
SET
P A S
Enter Password = 39
3 9
Press
Key
SET
C T R
C.T. Ratio
5
( 5-6000A )
Press
Key
SET
C O N
Configuration
3 P H
3 Phase
3 W
(3 Wire / 4 Wire )
Press
key to Save & exit
SET
IF Display Scroll
P A S
Enter Password = 59
5 9
Press
Key
SET
S C R
Scrolling
T I M
Time
5
( 1-99 Sec )
Press
key to Save & exit
SET
Need help?
Do you have a question about the MPD-192 and is the answer not in the manual?