Achieving Optimal Performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your
air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform
less than optimally.
Inverter Split Type
COOL mode
Room Temperature
17°C - 32°C (63°F -
90°F)
Outdoor
0°C - 50°C (32°F -
Temperature
122°F)
-15°C - 50°C (5°F -
122°F)
(For models with
low temp. cooling
systems.)
Fixed-speed Type
COOL mode
Room
Temperature 17°-32°C (63°-90°F)
18°-43°C (64°-109°F)
-7°-43°C (19°-109°F) (For models with
low-temp cooling systems)
Outdoor
Temperature
18°-52°C (64°-126°F) (For special tropical
models)
To further optimize the performance of your unit, do the following:
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and TIMER OFF functions.
• Do not block air inlets or outlets.
• Regularly inspect and clean air filters.
HEAT mode
DRY mode
0°C - 30°C (32°F -
10°C - 32°C
86°F)
(50°F - 90°F)
-15°C - 30°C
0°C - 50°C
(5°F - 86°F)
(32°F - 122°F)
HEAT mode
O°-30°C (32°-86°F)
-7°-24°C (19°-75°F)
FOR UNITS WITH
AUXILARY ELECTRIC
HEATER
When outside
temperature is below
0°C
), we strongly
(32°F
recommend keeping
the unit plugged in at
all timers to ensure
smooth ongoing
performance.
DRY mode
10°-32°C (50
-90°F)
o
11°-43°C (52°-109°F)
18°-43°C (64°-109°F)
18°-52°C (64°-126°F) (For
special tropical models)