Weight Of Cabinet Fronts; Aligning The Installation Niche - Miele MasterCool KF2902VI Operating And Installation Instructions

Fridge-freezer combination
Hide thumbs Also See for MasterCool KF2902VI:
Table of Contents

Advertisement

Installation

Weight of cabinet fronts

Before installing the cabinet fronts,
make sure that they do not exceed the
maximum permitted weight:
Appliance
Max.
weight of
upper cabi-
net front
KF 2802 Vi,
99 lb
KF 2812 Vi
(45 kg)
KF 2902 Vi,
88 lb
KF 2912 Vi
(40 kg)
Risk of damage due to excessive
weight of cabinet fronts.
Installing cabinet fronts which are
heavier than the maximum permitted
could damage the hinges.
This damage can affect various fac-
tors, such as operation of the appli-
ance.
Before installing the cabinet fronts,
make sure that they do not exceed
the maximum permitted weight.
28

Aligning the installation niche

Max.
weight of
lower cabi-
net front
40 lb
(18 kg)
22 lb
(10 kg)
The building-in niche must be carefully
aligned using a spirit level before the re-
frigeration appliance is installed. The
niche corners must be at 90° angles to
each other, otherwise the cabinet front
will not sit straight on all 4 corners of
the building-in niche.

Advertisement

Table of Contents
loading

Table of Contents