Bosch AquaStar 2400 EO Manual page 5

Table of Contents

Advertisement

Combustion
• NOx ≤ 55 ppm
• CO ≤ 250 ppm.
Dimensions
• Depth (in): 8 ½" (220 mm)
• Width (in): 15 ¾" (400 mm)
• Height (in): 26" (650 mm)
• Weight: 47 pounds (21 kg).
Gas types
Natural Gas.
LP Gas.
CO
analyzer is required to convert from one gas type
2
to another. Please contact BBTNA for specific
instructions.
Voltage
120 V AC (50/60 Hz)
Amperage
IDLE - 40 mA
Operation - ≤ 2,5 A
Noise
≤ 50 db (A)
Safety devices
• Flame failure device (ionization flame rod sensor)
• Pressure relief valve (supplied with heater)
• Over heat prevention (temperature limiter).
Water resistant
IP X5 (protection against water drops).
6 720 608 257
UNPACKING THE 2400 EO HEATER
This heater is packed securely.
The box includes:
• Control panel shield
• Pressure relief valve
• Bracket for wall hanging the heater
• Plastic decal shields for covering front cover screws
and control panel, installer should affix these decals
to the front of the unit after installation is complete.
See Fig. 6
• Installation manual
• Product registration card.
Do not lose this manual. Please complete and return
the enclosed product registration card.
Before installing the unit, be certain you have the
correct heater for your type of Gas - Propane or
Natural Gas. Identification labels are found on the
shipping box, and on the rating plate which is located on
the right side panel of the cover.
The 2400EO is not approved or designed for:
• Manufactured (mobile) homes, RV's or boats
• Heating or other recirculating/pumping applications*
• Solar/preheat backup or high temperature booster
use
* This includes domestic hot water circulator pump loop
systems that may previously exist in a home hot water
system. The use of a small electric mini-tank (4-6 gallon
size) should be used for this application; when
designed so the pump will circulate the hot water in the
mini-tank only and through the building's hot water
return loop (timed or thermostatic controlled operation
of the pump is commonly done). The 2400EO should
be plumbed in line before the mini-tank water heater,
contact BBTNA if further instruction is needed.
Appliance details
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquastar 2400 eo ngAquastar 2400 eo lp

Table of Contents