Prepare Electrical Wiring; Electrical Requirements - GE HDA2100HCC Installation Instructions Manual

Built-in & spacemaker dishwashers
Table of Contents

Advertisement

Available languages

Available languages

PREPARE ELECTRICAL WIRING

Remove all power leading to the
WARNING
appliance from the circuit breaker or
fuse box before beginning installation. Failure to do so
can result in a risk of electrical shock.
ADVERTENCIA
de disyuntor o de la caja del fusible antes de comenzar
con la instalación. Si no cumple con esto, se podrá
producir el riesgo de descargas eléctricas.

ELECTRICAL REQUIREMENTS

Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electric Code, ANSI/
NFPA 70 – latest edition, and all local codes and ordinances.
This appliance must have:
• 120V, 60Hz, AC-only, 15-ampere or 20-ampere, fused
electrical supply.
• Wiring must be 2 wire with ground and rated for 75°C (167°F).
• If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
It is recommended to have:
• A circuit breaker or time-delay fuse.
• A properly grounded individual branch circuit.
Grounding Instructions–Permanent Connection
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and be
connected to the equipment-grounding terminal or lead on
the appliance.
Grounding Instructions–Power Cord Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
for electric current. This appliance is equipped with a cord
having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet
that is installed and grounded in accordance with all local
codes and ordinances.
The improper connection of the
WARNING
equipment grounding conductor can
result in a risk of electric shock. Check with a qualified
electrician or service representative if you are in doubt that
the appliance is properly grounded. Do not modify the plug
provided with the appliance; if it will not fit the outlet, have
a proper outlet installed by a qualified technician.
ADVERTENCIA
tierra del equipamiento puede provocar un riesgo de
descarga eléctrica. Consulte a un electricista calificado
o representante de servicio técnico si tiene dudas sobre
la correcta conexión a tierra del aparato. No modifique el
enchufe que se suministra con el aparato; si no calza en el
tomacorrientes, haga que un técnico calificado le instale
un tomacorrientes adecuado.
Installation Preparation
Retire todos los conductores de
corriente del electrodoméstico
La conexión inadecuada del
conductor de conexión a
18"
Receptacle
Location
18"
Area
6"
6"
Cabinet Preparation & Wire Routing
The wiring may enter the opening from either side, rear
or the floor within the shaded area illustrated above
in figure and defined in PREPARE DISHWASHER
ENCLOSURE section.
• Cut a 1-1/2" maximum diameter hole to admit the
electrical cable. Edges of hole should be smooth and
rounded. Permanent wiring connections may pass
through the same hole as the drain hose and hot water
line, if convenient. If cabinet wall is metal, the hole
edge must be covered with a bushing.
NOTE:
Power cords with plug must pass through a
separate hole in the cabinet.
Cord Protector
(Obtain locally
as needed)
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
• For permanent connections the cable must be routed
as shown in figure. Cable must extend a minimum of
24" from the rear wall.
• For power cord connections, install a 3-prong
grounding type receptacle in the sink cabinet rear wall,
6" min. or 18" maximum from the opening, 6" to 18"
above the floor.
Use only WXO9X70910 (5' 5" long) or WX09X70911
(7' 11" long) Dishwasher Power Cord Kit. Do not use
an extension cord or adapter plug with this appliance.
5
Alternate Receptacle
Location in Adjacent
Cabinet
1-1/2" Dia. Hole (Max.)
3"
from
Cabinet
24"
from Wall
Ground
Black
White
M e t
a l C
a b i n
e t W
a l l
Hole Diameter
1-1/2" Maximum

Advertisement

Table of Contents
loading

Table of Contents