PREPARE ELECTRICAL WIRING

WARNING
FOR PERSONAL SAFETY: Remove house fuse or
open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this
appliance.

ELECTRICAL REQUIREMENTS

Be sure that the electrical connection and wire size are
adequate and in conformance with the National Electric
Code, ANSI/NFPA 70 – latest edition, and all local
codes and ordinances.
This appliance must have:
• 120V, 60Hz, AC-only, 15-ampere or 20-ampere, fused
electrical supply.
• Wiring must be 2 wire with ground and rated for 75°C
(167°F).
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
It is recommended to have:
• A circuit breaker or time-delay fuse.
• A properly grounded individual branch circuit.
Grounding Instructions–Permanent Connection
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
be connected to the equipment-grounding terminal or
lead on the appliance.
Grounding Instructions–Power Cord Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
for electric current. This appliance is equipped with a
cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an
appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances.
WARNING
The improper connection of the equipment grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative
if you are in doubt that the appliance is properly
grounded.
Installation Preparation
18"
Receptacle
Location
18"
Area
6"
6"
Figure E
WARNING
For models equipped with power cord: Do not
modify the plug provided with the appliance; if it will
not fit the outlet, have a proper outlet installed by a
qualified technician.
Cabinet Preparation & Wire Routing
The wiring may enter the opening from either side, rear
or the floor within the shaded area illustrated above in
Figure E and defined in Figure A.
• Cut a 1-1/2" maximum diameter hole to admit the
electrical cable. Edges of hole should be smooth and
rounded. Permanent wiring connections may pass
through the same hole as the drain hose and hot water
line, if convenient. If cabinet wall is metal, the hole
edge must be covered with a bushing.
NOTE:
Power cords with plug must pass through a
separate hole in the cabinet.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
• For permanent connections the cable must be routed
as shown in Figure E. Cable must extend a minimum of
24" from the rear wall.
• For power cord connections, install a 3-prong
grounding type receptacle in the sink cabinet rear wall,
6" min. or 18" maximum from the opening, 6" to 18"
above the floor.
Use only WX09X70910 or WX09X70911 Dishwasher
Power Cord Kit.
4
Alternate Receptacle
Location in Adjacent
Cabinet
1-1/2" Dia. Hole (Max.)
3"
from
Cabinet
24"
from Wall
Ground
Black
White