Delta OHM HD32.7 Manual
Delta OHM HD32.7 Manual

Delta OHM HD32.7 Manual

Rtd datalogger

Advertisement

Quick Links

REV. 1.2
12/12/2016
HD32.7
RTD DATALOGGER
ENGLISH
Our instruments' quality level is the results of the product continuous development. This
can bring about differences between the information written in this manual and the
instrument that you have purchased. We cannot entirely exclude errors in the manual, for
which we apologize.
The data, figures and descriptions contained in this manual cannot be legally asserted. We
reserve the right to make changes and corrections without prior notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD32.7 and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta OHM HD32.7

  • Page 1 REV. 1.2 12/12/2016 HD32.7 RTD DATALOGGER ENGLISH Our instruments’ quality level is the results of the product continuous development. This can bring about differences between the information written in this manual and the instrument that you have purchased. We cannot entirely exclude errors in the manual, for which we apologize.
  • Page 2 RTD Datalogger HD32.7 - 2 -...
  • Page 3 HD32.7 1. ON/OFF key: It turns the instrument on and off. 2. TIME key: It allows the display of date and time, in the first line for about 8 seconds. 3. SHIFT FNC key: It activates the Shortcut window. 4. Graphic display.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS 1. GENERAL CHARACTERISTICS ........................6   2. KEYBOARD AND DISPLAY DESCRIPTION ....................7   2.1 T ..............................7   ISPLAY ............................... 7     EYBOARD 3. OPERATION ...............................10   3.1 T “U ” .........................10   HE UNIT OF MEASUREMENT 3.2 T ..........10  ...
  • Page 5 11. CONNECTION TO A PC ..........................38   11.1 C RS232C ....................38   ONNECTION TO THE SERIAL PORT 11.2 C USB 2.0 ........................38   ONNECTION TO THE PORT 12. FUNCTIONING NOTES AND OPERATING SAFETY ..................39   13. TECHNICAL CHARACTERISTICS ........................40   14.
  • Page 6: General Characteristics

    1. GENERAL CHARACTERISTICS The HD32.7 RTD datalogger is an instrument that can capture, log and then send to a PC or serial printer the data coming from 8 temperature probes with Pt100 or Pt1000 sensor connected to the inputs. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000. All the connected probes must be of the same type.
  • Page 7: Keyboard And Display Description

    Pt1000) is selected from the menu. (Please see the “Input” paragraph on page 22.) 2.1 The Display The HD32.7 standard display is divided in two areas: The first area displays the battery’s charge status and the current time (above); then, the temperatures measured by the probes connected to the inputs (below) arranged on two columns.
  • Page 8 NOTE: The non-connected inputs will be indicated by dashes. If a probe is disconnected when the instrument is on, the “LOST” message will be displayed in case of a SICRAM probe, or dashes in the other cases: Reconnect the probe to read the measured temperature. Do not connect the probes when the instrument is on: In order to correctly detect them, you need to turn the instrument off and then back on again.
  • Page 9 ENTER key In the menu, it confirms the entered data. ESC key It allows to exit from the menu or, in case of a submenu, to move up one level. MEM key It allows to start and end a “logging” session (data recording); the data logging interval must be set in the menu.
  • Page 10: Operation

    3. OPERATION Before turning on the instrument, connect the probes to the 8-pole male DIN45326 inputs, located in the lower part of the instrument (see figure on page 2). All probes must be of the same type: The selection of the type of probe should be performed in the Input menu item (please see page 22).
  • Page 11: Instrument Setup

    4. The three items max (maximum), min (minimum) and avg (average) are shown in the bottom line of the display using F1 or F2. NOTE: Once selected, for example max, all displayed quantities represent the maximum value. The average is calculated on the first five minutes of samples, and then on the current average.
  • Page 12: Main Menu

    4. MAIN MENU To access the programming menu press SETUP: The setting menu will be displayed with the following items: 0) Info 1) Logging 2) Serial 3) Input 4) Contr. 5) Firmware 6) Time/date 7) Calibrate 8) Key lock 9) Password If you do not press any key within 2 minutes, the instrument goes back to the main display.
  • Page 13: Logging

    4.2 Logging To access the Logging menu, open the main menu using the SETUP key. Using the ▲▼ ◄► arrows, select Logging and confirm with ENTER. The parameter setting submenu for the logging sessions will be displayed. You can set the data capture frequency (Log interval) and the automatic logging start (Start/stop time).
  • Page 14: Start/Stop Time

    to turn off the instrument between loggings: it will turn on 15 seconds before the sampling and will turn off immediately afterwards, thus increasing the battery life. Once you have accessed the LOGGING submenu (previous par.) use the arrows ▲ ▼ to select Self shut-off mode: •...
  • Page 15 1. Press ENTER to confirm the data prompted by the instrument; 2. To change the prompted data, use the arrows ◄ ► to select the data to be changed (year/month/day and hour:minutes:seconds); 3. The selected data will flash; 4. Use the arrows ▼▲ to change its value; 5.
  • Page 16 10. Press ENTER to confirm or ESC to exit without enabling the automatic start: In both cases, you will return to the LOGGING menu. 11. Press SETUP to exit immediately from the main menu. When the instrument starts automatically a LOG session, a beep is issued on each capture and the blinking LOG message is shown at the top of the display.
  • Page 17: Cancel Auto Start

    4.2.4 Cancel auto start Once the LOG session start and end times are set, you can inhibit the session automatic start by using Cancel auto start. Once you have accessed the LOGGING submenu: 1. Use the arrows ▲ ▼ to select Cancel auto start 2.
  • Page 18 Once you have accessed the LOGGING submenu: 1. Use the arrows ▲ ▼ to select Log File manager: You will see the following submenu 0) Print selected log 1) Erase ALL logs 2) Select memory type 2. Use the arrows ▲▼ to select a menu item; 3.
  • Page 19 0) Print selected log: By selecting this item, the page of the log to be printed will be displayed: 1. Use the arrows ▲▼◄►to select the log to be printed, and the F1 and F3 function keys to shift page. 2.
  • Page 20: Serial (Serial Communication)

    The memory can be handled in two modes that can be selected using the ▲▼ arrows: • Circular memory. When the memory is full, the new files will overwrite the oldest ones. • Until memory full. When the memory space is full, the recording will stop and the message “WARNING: MEMORY FULL!!”...
  • Page 21: The Baud Rate

    4.3.1 The Baud Rate The Baud Rate indicates the speed used for the serial communication with the PC. To set the Baud rate, proceed as follows: 1. Use the arrows ▲▼ to select the item; 2. Press ENTER: You will get the following message: 3.
  • Page 22: Input

    data printing is started when the PRINT key is pressed. Press PRINT again to end the continuous printing. Select a sufficiently long print interval so that the printer connected to the instrument can actually perform the printing. 4.4 Input The instrument accepts the input of Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2- wire Pt1000 probes.
  • Page 23: Firmware

    5. Use the arrows ◄► to decrease or increase the contrast; 6. Press ENTER or ESC to return to the main menu; 7. Press SETUP to exit immediately from the main menu. Note: Without opening the menu, you can modify the contrast directly on the display during the measurement, using the ◄►...
  • Page 24: Calibrate

    5. Use the arrows ◄ ► to select the data to be set (year/month/day and hour:minutes); 6. Once selected, the data will start blinking; 7. Use the arrows ▼▲ to enter the correct value; 8. Press ENTER to confirm and return to the main menu; 9.
  • Page 25: Password

    1. Press SETUP; 2. Use the arrows ▲▼◄► to select Key lock; 3. Press ENTER; 4. You will get the following message: “Enter the password to lock the keyboard” 5. Use the arrows ▼▲ to enter the correct password; 6. Press ENTER to confirm (or ESC to cancel); By pressing ENTER you return to the main menu and the instrument keyboard is locked: A “key”...
  • Page 26 5. Use the arrows ▲▼ to select User password; 6. You will get the message “Insert old password” The default password is “0000” (four zeroes). 7. Use the ▼▲ arrows to enter the current password; 8. Press ENTER to confirm (or ESC to cancel); 9.
  • Page 27: Probes And Measurements

    5. PROBES AND MEASUREMENTS The instrument works with Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000 temperature probes. All connected probes must be of the same type: You cannot simultaneously connect probes of different types. The excitation current was chosen in order to minimize the sensor self-heating effects.
  • Page 28: Temperature Measurement

    5.3 Instructions to connect the TP47 connector for 4-wire Pt100 and 2-wire Pt1000 probes All Delta Ohm probes are provided with a connector. The HD32.7 instrument also work with direct 4-wire Pt100, and direct 2-wire Pt1000 probes built by other manufacturers: For the instrument connection you have to use the TP47 connector, to which the probe’s wires should be welded.
  • Page 29 Do the following to open the module and connect a probe: Unscrew the fairlead and extract the gasket, remove the label using a cutter, unscrew the ring on the opposite side as illustrated in the figure: Open the two module shells: The printed circuit to which the probe must be connected is housed inside.
  • Page 30: Direct Connection Of 4-Wire Pt100 And 2-Wire Pt1000 Sensors To The Din45326 8-Pole Female Connectors

    5.3.1 Direct connection of 4-wire Pt100 and 2-wire Pt1000 sensors to the DIN45326 8-pole female connectors The 4-wire Pt100 and 2-wire Pt1000 Sensor Direct connection to the connector sensor can be welded directly on the female connector’s pins, without using the TP47 card.
  • Page 31: Instrument Signals And Faults

    6. INSTRUMENT SIGNALS AND FAULTS The following table lists the instrument indications, the errors and the information supplied to the user. Display indication Explanation This appears if the sensor is not present or is faulty. This appears also if the correct sensor was not set in the menu: Pt100 SICRAM, direct ---.-- 4-wire Pt100 or direct 2-wire Pt1000.
  • Page 32: Battery Symbol And Battery Replacement, Mains Power Supply

    7. BATTERY SYMBOL AND BATTERY REPLACEMENT, MAINS POWER SUPPLY The battery symbol on the display constantly shows the battery charge status. To the extent that batteries have discharged, the symbol “empties”. When the charge decreases still further it starts blinking. In this case, batteries should be replaced as soon as possible.
  • Page 33: Warnings About Battery Use

    The external power supply connector has an external diameter of 5.5mm and an internal diameter of 2.1mm. Warning: The power supply cannot be used as a battery charger. If the instrument is connected to the external power supply, the symbol is displayed instead of the battery symbol Malfunctioning upon turning on, after battery replacement After replacing the batteries, the instrument may not restart correctly;...
  • Page 34: Serial Interface And Usb

    9. SERIAL INTERFACE AND USB The HD32.7 is fitted with an electrically isolated RS-232C serial interface, and an USB 2.0 interface. Optionally, we can supply a serial cable with sub D 9-pole female connectors (code 9CPRS232) or a cable with USB 2.0 connectors (code CP22).
  • Page 35 Command Response Description Firm.Date=2005/10/12 Firmware date cal 0000/00/00 00:00:00 Calibration date and time User ID=0000000000000000 User code (set with T2xxxxxxxxxxxxxxxx) Print instrument’s heading & Stop printing data & Immediate printing of data & Start logging data & Stop logging data &...
  • Page 36: Storing And Transferring Data To A Pc

    10. STORING AND TRANSFERRING DATA TO A PC The HD32.7 instrument can be connected to a personal computer via an RS232C serial port or USB port, and exchange data and information through the Deltalog9 software (vers. 3.0 and later) running in a Windows operating environment. It is possible to print the measured values on an 80 column printer (PRINT key) or store them in the internal memory using the Logging function (MEM key).
  • Page 37: The Erase Function: Clearing The Memory

    10.1.2 The Erase function: clearing the memory To clear the memory use the Erase Log function (see par. “4.2.5 Log File Manager”). The instrument starts clearing the internal memory; at the end of the operation, it goes back to normal display.
  • Page 38: Connection To A Pc

    11. CONNECTION TO A PC The HD32.7 is fitted with two ports for connecting the instrument to the PC: RS232C serial port with null modem cable code 9CPRS232. The cable has two sub D 9-pole female connectors. USB 2.0 port with the cable code CP22. The cable has a USB type A connector for PC connection and a USB type B connector for connection to the instrument.
  • Page 39: Functioning Notes And Operating Safety

    12. FUNCTIONING NOTES AND OPERATING SAFETY Authorized use Comply with the technical specifications outlined in the next chapter. Its use is authorized only in conformity with the instructions written in this manual. Any different use is considered improper. General instructions on security This instrument has been manufactured and tested according to safety regulation EN 61010-1:2010 concerning electronic measurement instruments and was delivered ex factory in perfect security conditions.
  • Page 40: Technical Characteristics

    13. TECHNICAL CHARACTERISTICS Instrument Dimensions (Length x Width x Height) 220x180x50 mm Weight 1100 g (batteries included) Materials ABS, polycarbonate and aluminium Display Backlit, Dot Matrix 128x64, visible area 56x38mm Type of probes Pt100 SICRAM, direct 4-wire Pt100, direct 2-wire Pt1000 Temperature measurement (from vers.
  • Page 41 Memory Divided in 64 blocks. Storage capacity 96,000 records from 8 inputs each. Logging interval Selectable among: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes, and 1 hour. Internal clock accuracy 1min/month max. departure RS232C serial interface Type RS232C electrically isolated...
  • Page 42 13.1 Technical data of the probes complete with SICRAM module for the instrument TEMPERATURE PROBES Pt100 WITH SICRAM MODULE Model Type Application range Accuracy ±0.25°C (-196°C…+300°C) TP472I Immersion -196°C…+500°C ±0.5°C (+300°C…+500°C) TP472I.0 Immersion -50°C…+300°C ±0.25°C 1/3 DIN – Thin Film ±0.25°C (-50°C…+300°C) TP473P.I Penetration...
  • Page 43 Probes Pt100 4 wires and Pt1000 2 wires Model Type Application range Accuracy TP47.100.O Pt100 4 wires -50…+250°C 1/3 DIN 1/3 DIN – Thin Film TP47.1000.O Pt1000 2 wires -50…+250°C 1/3 DIN 1/3 DIN – Thin Film TP87.100.O Pt100 4 wires -50…+200°C 1/3 DIN 1/3 DIN –...
  • Page 44: Ordering Codes

    HD32.7 8-input data logger instrument for temperature probes fitted with Pt100 sensor complete with SICRAM module. The kit is composed of the HD32.7, 4 1.5V alkaline C-BABY type batteries, operating manual, DeltaLog9 software (vers. 3.0 and later), and bearing and transport belt. The probes, support, suitcase and cables must be ordered separately.
  • Page 45 Tripod complete with 6 input head and 5 probe holder, code HD3218K. HD3218K Rod for another probe. DELTA OHM metrology laboratories LAT N° 124 are accredited by ACCREDIA for Temperature, Humidity, Pressure, Photometry / Radiometry, Acoustics and Air Velocity. They can supply calibration certificates for the accredited quantities.
  • Page 46 - 46 -...
  • Page 47 DICHIARAZIONE DI CONFORMITÀ UE EU DECLARATION OF CONFORMITY GHM Messtechnik GmbH location Delta OHM, via G. Marconi 5, 35030 Selvazzano (PD), Italy Documento Nr. / Mese.Anno: 5023 / 12.2016 Document-No. / Month.Year : Si dichiara con la presente, in qualità di produttore e sotto la propria responsabilità esclusiva, che i seguenti prodotti...
  • Page 48 All DELTA OHM instruments are subject to accurate testing, and are guaranteed for 24 months from the date of purchase. DELTA OHM will repair or replace free of charge the parts that, within the warranty period, shall be deemed non efficient according to its own judgement. Complete replacement is excluded and no damage claims are accepted.

Table of Contents