1 INTRODUCTION HD32MT.3 data logger is able to acquire and store measured data from a series of environ- mental sensors connected to its inputs. The data logger has an SDI-12 port, to which you can connect up to four sensors, and an RS485 port with Modbus-RTU protocol for connecting Delta OHM sensors, such as: HD52.3D…...
Page 5
The connection to a PC through the USB port of the data logger does not require the installation of any USB driver: when connecting the instrument to a PC, the Windows® operating system auto- matically recognizes the instrument as an HID device (Human Interface Device) and uses the driv- ers already present in the operating system. HD32MT.3 V1.2...
Page 6
The data loggers equipped with the optional GSM/UMTS module can automatically send, at regular intervals, the data to the Delta OHM portal “www.deltaohm.cloud”. This allows you to view the data from anywhere in the world, even by using mobile devices (tablet, smartphone, notebook), simply having an Internet connection and using a web browser.
Materials Hot-pressed, fiber glass reinforced polyester case. Protection shield against solar radiation in powder-coated anodized aluminum. Case dimensions 355x260x200 mm (anti-radiation shield included). Weight About 7 kg Case protection degree IP 66 Case certifications In compliance with UL/CSA/AS HD32MT.3 V1.2...
Page 8
Note: the internal temperature sensor is used to monitor the internal temperature of the box that cannot match the outside temperature due to heating given by the operation of the elec- tronic board and the lack of air exchange inside the locked box. HD32MT.3 V1.2...
To extract the card, press it until you hear the release click. For a safe extraction of the card, use the dedicated menu function. Access hole for the display contrast adjustment screw. 4-lines dot-matrix LCD display and keyboard. HD32MT.3 V1.2...
2. SDI-12 and auxiliary serial communication ports (COM AUX). The auxiliary serial port can operate in RS232, RS485 or RS422 mode with proprietary protocol or in RS485 mode with Modbus-RTU protocol (“Modbus Slave” mode). Terminal Function number SDI-12 data line. RS422 RS485 RS232 DATA- DATA+ HD32MT.3 V1.2...
Page 11
Up to 4 sensors (with address from 1 to 4), whose measurements (up to 8 for each sensor) are acquired every 10 seconds, can be connected to the SDI-12 line. 3. RS485 communication port with Modbus-RTU protocol (COM SENSORS) adapted for the connection of Delta OHM sensors. Terminal Function...
Page 12
First pole of the rain gauge output contact Second pole of the rain gauge output contact 9. Input "SW IN" for the connection of the sensor (with potential-free contact output) for sig- nalling the opening of the case cover. HD32MT.3 V1.2...
Page 13
0...20 mA fields and dip switches must be set to 1 V. Terminals for the connection of GSM/UMTS modules. This connection supports RS232 se- rial port. Terminal Function number +Vsw3 (module positive power supply) GND (module negative power supply) HD32MT.3 V1.2...
The adapter must be configured with the serial communication parameters 115200 b/s, 8N2. To configure the serial communication parameters and the IP address of the adapter HD5110, use the configuration software supplied with the adapter, referring to the relevant instructions. HD32MT.3 V1.2...
The tray is provided with an insertion key that prevents the possibility of inserting the SIM card improperly. 4. Put the SIM tray back in place, making sure that the SIM card contacts face the cover of the data logger housing. 5. Reconnect the power supply. HD32MT.3 V1.2...
2. Wrong position of the solar panel towards the North: orient it towards the South (in the northern hemisphere). 3. Wrong position of the rain gauge. Install it far from station. HD32MT.3 V1.2...
Page 18
2) To ensure a good protective earth connection of the equipments metallic parts. It is recommended to connect all the equipments to a single ground point, to avoid currents generated by several points at different potentials (ground loop) that may cause measurement errors. HD32MT.3 V1.2...
24 = reset performed after Watchdog activation. The menu allows the data logger to perform the following operations: Safe removal of the SD card. Safe removal of the SIM card from GSM/UMTS module. Resettin of the rainfall quantity partial counter. HD32MT.3 V1.2...
Page 20
Remove SIM CARD Enter to confirm NEVER REMOVE SD Press ENTER again to confirm the SIM card removal, or press ESC to exit. The data log- ger automatically exits the menu if ENTER is not pressed within 15 seconds. HD32MT.3 V1.2...
Page 21
Press ENTER again to confirm that you want to clear the rainfall quantity partial counter or press ESC to exit. The data logger automatically exits the menu if ENTER is not pressed within 15 seconds. INCR. COUNTER WAS RESET After reset, the data logger automatically exits the menu. HD32MT.3 V1.2...
The internal EEPROM memory of the data logger is operated in a circular way: when the memory is full, new data will overwrite the oldest. The internal memory can store up to about 56 hours recording with fixed 10 seconds logging interval, and can store up to 8191 pulses of the rain gauge. HD32MT.3 V1.2...
USB or make any settings. Therefore, in the Meteo Studio software you will have to close the transfer of data before performing other func- tions. However, it remains always functional the communication through the auxiliary serial port (COM AUX). HD32MT.3 V1.2...
1 to 9 seconds, recording the measures with index 17 and 18 and configuring the anemometer to use the scalar method for the calculation of the average (not the default method, please refer to the manual of HD52.3D ...). HD32MT.3 V1.2...
Page 25
1 to 9 seconds, recording the measures of index 17 and 18 and configuring the anemometer to use the vector method for the calculation of the average (this is the default method, see the manual HD52.3D ...). HD32MT.3 V1.2...
Example: If a rain gauge with 0.200 mm nominal resolution has a correct resolution of 0.212 mm when the rainfall rate is 100 mm/h, the interval in seconds between two subsequent emptying of the bucket is equal to: HD32MT.3 V1.2...
Page 27
). The uncompensated value of the amount of rain instead is not recalculated based on the new resolution. To avoid inconsistent measures, it is recommended to reset the counters when changing the nominal resolution of the rain gauge. HD32MT.3 V1.2...
0...1 V and measuring range -40 ... +60 °C. The values required for the calculation of offset and gain are therefore: = -40 °C = +60 °C = 0 V = 1 V The values of the parameters offset and gain are: HD32MT.3 V1.2...
Page 29
= 1100 mbar = 0.2 V = 1 V The values of the parameters offset and gain are: 1100 1100 Offset Gain To the analog input must be associated the unit of measurement of index 4 (hPa = mbar). HD32MT.3 V1.2...
SMS. Alternatively, make the settings with the help of Meteo Studio software. Other specific SMS alerts are sent when specific events occur, for example for a reset of the logger, when the SD card is removed, when an error occurs to clock synchronization, etc. HD32MT.3 V1.2...
For the update is used an http connection and the web server must respond to port 80 in a standard way. TESTCLOCKSYNC Synchronize the date and time of the data logger with the date and time of the web server set. HD32MT.3 V1.2...
The units of index 27, 28 and 29 (user1, user2, and user3) are defined by the user with the command USERUNITNAME. They are provided to associate to the quantities measured by the sensors connected to the three analog inputs units not included in the list of predefined units HD32MT.3 V1.2...
(YES = sensor activated, NO = sensor disabled). LISTTYPECODES Prints the list of the types of storage available. 1=Instant Value 2=Mean Value 3=Maximum Value 4=Minimum Value 5=Total (for measures of impulsive type, eg. rainfall) HD32MT.3 V1.2...
Page 34
Temperature at +5 cm measured by TP32MTT.03 m=42 Barometric pressure measured by HD9408.3B m=43 Temperature measured by HD9408.3B m=44 Quantity corresponding to analog input C m=45 Volumetric water content measured by HD3910... m=46 Apparent dielectric permittivity measured by HD3910... HD32MT.3 V1.2...
Page 35
HD3910 status register m=104 Saturated Vapour Pressure (SVP) measured by HD52.3D... m=105 Partial Vapour Pressure (PVP) measured by HD52.3D... m=106 Wet bulb temperature measured by HD52.3D... m=107 Wind speed measured by HD2003... m=108 Wind direction measured by HD2003... HD32MT.3 V1.2...
The offset and slope are obtained from the technical data of the ane- mometer. The values to be set for the anemometer HD54.3 are a =0.35 and b = 0.765. WINDVANEOFFS Prints the offset value of the wind vane. HD32MT.3 V1.2...
2 successive pulses <15s 1.000 (0%) if interval between 2 successive pulses <30s RAINTOTALS Prints the total and partial amount of rain, both uncompensated and compensated according to the correction table, and the instants of counters reset. HD32MT.3 V1.2...
If b = Y, shows the amount of rain compensated in accordance with the correction table. 11.9 HD2016 RAIN GAUGE SETTINGS Command Description HD2016RESET Prints the date and time of the last reset of the partial rainfall counter. HD2016RESET Y Resets the partial rainfall counter. HD32MT.3 V1.2...
Sets the unit of measurement of index u and the resolution r for the measurement number m (m=1...8) of the SDI-12 sensor with address n (n=1...4). See the command LISTUNITCODES for the list of the units of measure- ment. r is the number of decimals of the measure (r=0...7). HD32MT.3 V1.2...
Prints if the alarm relay must report the condition of low battery. RELAYONBATTERY b Sets whether the alarm relay must report the condition of low bat- tery. If b=Y, the relay indicates the low level battery status. If b=N, the relay does not indicate the low level battery status. HD32MT.3 V1.2...
Prints the enable status of the transmission by e-mail and/or FTP of files of type T2. T2TRANSMIT b Sets whether to enable or not the transmission by e-mail and/or FTP of files of type T2. If b=Y the transmission is enabled, if b=N the transmission is disabled. HD32MT.3 V1.2...
Page 42
Note: If the command LISTFILEQUEUE is sent via SMS rather than via serial, you will receive only the last line of the printout with the values FifoIN, FTPOUT and EMAILOUT. HD32MT.3 V1.2...
(to copy to the SD card with the name "ftptst.txt") or, in the absence of the user file, a default file (named "xftptst.txt") created by the data logger. Note: if a parameter is not set, the data logger response is "?VOID|". HD32MT.3 V1.2...
TEST indication is added to the SMS content to indicate that the SMS has not been sent due to the alarm occurrence. TESTSMS "c...c" Sends an SMS containing the string c...c (max 64 characters) to all the stored phone numbers. HD32MT.3 V1.2...
Page 45
Sets the meteorological data collection site where the recorded data have to be transmitted. Delta OHM portal c=W www.wunderground.com www.pwsweather.com no site PORTALURLADDRESS Prints the Internet address of the Delta OHM portal. If the address is not set, the datalogger responds "? VOID |". HD32MT.3 V1.2...
Page 46
If the path is not set, the datalogger responds "? VOID |". PORTALSERVER c...c Sets the string c...c as folder path for saving data in the Delta OHM portal. Note: at the end of the string c...c it is automatically added the da- ta logger serial number, followed by /data for the logged data or /config for the configuration data.
Page 47
Sent within 60 seconds from the data logger power up or reset, dis- ables the Modbus-RTU protocol for the COM AUX port with RS485 in- terface ("Modbus slave" mode) until a new data logger reset (to permanently disable the Modbus-RTU protocol, use the command MBENABLE). HD32MT.3 V1.2...
Page 48
VSWCONTROL n b Enables/disables the switched power output Vsw number n (n=1,2,3). If b=Y, the output is enabled (powered). If b=N, the output is disabled (not powered). If b=C, an ON/OFF cycle of the power output is performed. HD32MT.3 V1.2...
Page 49
Commands that might produce too long responses to be contained in a SMS text are not avail- able via SMS. Some commands, however, are not available via SMS to preserve the security of the system (for example, the mobile phone number with index 0 cannot be changed with the command PHONE sent via SMS). HD32MT.3 V1.2...
Page 50
The user of the instruments must ensure compliance with the following standards and guide- lines for the treatment of hazardous materials: EEC directives on workplace safety National low regulations on workplace safety Accident prevention regulations HD32MT.3 V1.2...
Page 51
USB connecting cable, 4 GB SD memory card, operating manual. The fixing accessories are included. It includes Meteo Studio software downloadable from Delta OHM web site. 17…26 Vdc power supply. It can be powered from 100…240 Vac mains by using the optional AC/DC external power supply unit HD32MT.SWD.
Page 52
2 spare charges, bubble level for alignment and Calibration Report. RS485 serial output with MODBUS-RTU protocol. 5÷30Vdc power supply. Upon request, CPM12-8P… 2, 5 or 10 m cables with 8-pole M12 female connector. HD32MT.3 V1.2...
Page 53
. 3000 cc collecting reservoir. Automatic water discharge. Operating temperature from +4 °C to +60 °C. RS485 Mod- bus-RTU or SDI-12 output. Voltage-free output contact (NO). Power supply: 10…15 Vdc. Adjustable feet for ground installation included in the kit. HD32MT.3 V1.2...
Page 54
40 mm diam. extensions and accessories. For HD54.3 and HD54.D. PFV.30W 30W monocrystalline photovoltaic panel. For use with 12 V battery and bat- tery charger included inside the housing. HD2004.30K Kit for photovoltaic panel fastening. HD978TR5 Signal converter/amplifier with mV input and 4…20 mA output. HD32MT.3 V1.2...
Page 55
HD978TR6 Signal converter/amplifier with mV input and 0…10 V output. Delta OHM LAT N° 124 metrology laboratories are ISO/IEC 17025 accredited by ACCREDIA in Temperature, Humidity, Pressure, Photometry/Radiometry, Acoustics and Air Speed. They can provide certificates for the accredited quantities.
Page 60
All DELTA OHM instruments are subject to accurate testing, and are guaranteed for 24 months from the date of purchase. DELTA OHM will repair or replace free of charge the parts that, within the warranty period, shall be deemed non efficient according to its own judgement. Complete replacement is excluded and no damage claims are accepted.
Page 61
GHM GROUP – Delta OHM | Delta Ohm S.r.l. a socio unico Via Marconi 5 | 35030 Caselle di Selvazzano | Padova | ITALY Phone +39 049 8977150 | Fax +39 049 635596 www.deltaohm.com | info@deltaohm.com The quality level of our instruments is the result of the constant development of the product. This may produce some differences between the information written in this manual and the instrument you have purchased.
Page 62
GHM GROUP – Delta OHM | Delta Ohm S.r.l. a socio unico Via Marconi 5 | 35030 Caselle di Selvazzano | Padova | ITALY Phone +39 049 8977150 | Fax +39 049 635596 www.deltaohm.com | info@deltaohm.com V1.2 06/03/2018...