INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
This appliance may be installed in an
aftermarket, permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by state or local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
FAN TYPE
DIRECT - VENT WALL
FURNACE MODEL:
DVC55SPPXLP - 2
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
DVC55SPPXNAT - 2
UL FILE NO.
MH46706
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Heating Systems DVC55SPPXLP-2

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL FAN TYPE INSTALLER: DIRECT - VENT WALL Leave this manual with the appliance. CONSUMER: FURNACE MODEL: Retain this manual for future reference. DVC55SPPXLP - 2 DVC55SPPXNAT - 2 WARNING FIRE OR EXPLOSION HAZARD If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ......................3 Safety Information for Users of Propane Gas ................4 Requirements for Massachusetts ....................5 Introduction ..........................6-7 Specifications ..........................7 Gas Supply ..........................8-9 Clearances ..........................9 Installation Instructions ......................10-12 Lighting Instructions .........................13 Pilot Flame Characteristics ......................14 Main Burner Flame Characteristics ..................14 Wiring ............................15 Service and Maintenance Suggestions ..................16...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be • DO NOT put anything around the furnace that will located out of traffic and away from furniture and obstruct the flow of combustion and ventilation air.
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and explo- SOME POINTS TO REMEMBER sions. In its natural state, propane is odorless and colorless. • Learn to recognize the odor of Propane Gas. Your local Propane You may not know all the following safety precautions which Gas Dealer can give you a "Scratch and Sniff"...
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be per- in every dwelling, building or structure used in whole or in part for manently mounted to the exterior of the building at a minimum residential purposes, including those owned or operated by the height of eight (8) feet above grade directly in line with the Commonwealth and where the side wall exhaust vent termination...
  • Page 6: Introduction

    INTRODUCTION Introduction Installation in Residential Garages Always consult your local Building Department regarding regulations, Gas utilization equipment in residential garages shall be installed so codes or ordinances which apply to the installation of a direct vent that all burners and burner ignition devices are located not less than wall furnace.
  • Page 7: Specifications

    Side Outlet Kit, 10" Boot Assembly with Register VINYL SIDING VENT KITS Model Number Description DV-822 Vinyl Siding Vent Kit VSK2 Vinyl Siding Vent Kit CONVERSION KITS Part Number Description Used On 45060 Propane to Natural DVC55SPPXLP-2 45059 Natural to Propane DVC55SPPXNAT-2 45050-0-0523 Page 7...
  • Page 8: Gas Supply

    GAS SUPPLY Locating Gas Supply The gas lines must be checked for leaks by the installer. This should The gas line can enter the unit either through the floor or outside be done with a soap solution watching for bubbles on all exposed wall.
  • Page 9: Clearances

    GAS SUPPLY (CONT'D) Checking Manifold Pressure outlet with the inlet pressure to the valve from a minimum of 11.0" Both Propane and Natural Gas valves have a built-in pressure w.c. for the purpose of input adjustment to a maximum of 13.0" w.c. regulator in the gas valve.
  • Page 10: Installation Instructions

    INSTALLATION INSTRUCTIONS Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
  • Page 11 INSTALLATION INSTRUCTIONS (CONT'D) Cutting Vent Tubes This is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diameter flue outlet tube are to be marked and cut using the following procedure. Attach 6"...
  • Page 12 INSTALLATION INSTRUCTIONS (CONT'D) Installing a Vent Near a Window Ledge, WARNING Other Type of Projection or on Siding (vinyl, aluminum, etc.) Direct vent furnaces are designed to be installed on a uniform out- When vinyl siding vent kit, DV-822 or 2" x 4" framing is added side wall.
  • Page 13: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. C.
  • Page 14: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The correct pilot flame (Figure 11) will be blue, extending past PROPER FLAME ADJUSTMENT the thermocouple. The flame will surround the thermocouple just below the tip. Natural Gas pilots require adjusting when the inlet gas pressure is above 5"...
  • Page 15: Wiring

    WIRING Wiring The appliance, when installed, must be electrically grounded SCHEMATIC WIRING DIAGRAM in accordance with local codes or, in the absence of local —————————————————————————————— SCHÉMA INSTALLATION LECTRIQUE É codes, with the National Electrical Code, ANSI/NFPA 70 or WHITE (BLANC) MOTOR Canadian Electrical Code, CSA C22.1, if an external electrical —————...
  • Page 16: Service And Maintenance Suggestions

    SERVICE & MAINTENANCE SUGGESTIONS Replacing Fan and Oiling the Motor If Electrode Does Not Produce Spark: The fan motor should be cleaned and oiled once each heating season. Check wire connections. To reach the motor, withdraw the metal shroud surrounding the fan Check gap for pilot burner to the electrode tip.
  • Page 17: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide war- ranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below.
  • Page 18: Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index Part Index Part Description Description 11762 Outer Casing Top DV064 Cover Plate for Observation Hole R618 Motor Mount (Four Required) 45058 Seal Bracket 11764...
  • Page 19: Parts View

    PARTS VIEW 21 22 45050-0-0523 Page 19...
  • Page 20: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 21 INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE INSTALLATEUR : RADIATEUR MURAL Laissez cette notice avec l’appareil. À CIRCULATION FORCÉE CONSOMMATEUR : AVEC UN ÉVENT DIRECT Conservez cette notice pour consultation ultériure. MODÈLES : DVC55SPPXLP - 2 DVC55SPPXNAT - 2 AVERTISSEMENT RISQUE D’INCENDIE OU D’EXPLOSION Si les informations contenues dans ces instructions ne sont pas suivies à...
  • Page 22 La description L’assemblage d’évent pour le DV-822 revêtement en vinyle L’assemblage d’évent pour le VSK2 revêtement en vinyle KITS DE CONVERSION Numéro de parte La description Utilisé sur 45060 Propane to Naturel DVC55SPPXLP-2 45059 Naturel to Propane DVC55SPPXNAT-2 Page 2 45050-0-0523...
  • Page 23 Lorsqu’un radiateur de catégorie 1 existant est retiré ou remplacé, le sys- ment indiquer les effets d’un système de ventilation de taille inadéquate tème de ventilation d’origine peut ne plus être dimensionné pour ventiler (formation de condensat, fuite, déversement, etc.) et doivent spécifier la correctement les appareils raccordés.
  • Page 24 INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des famille. Un jour, lorsqu’il n’y aura pas une minute à perdre, la explosions. Dans son état naturel, le propane est inodore et sans sécurité...
  • Page 25 Agence d’Installation Qualifiée l'ouverture du mur. S'il y a une isolation au-dessus de l'ouverture L’installation et le remplacement des tuyaux à gaz, des équipements murale (tube d'entrée d'air), une barrière doit être installée au-dessus ou accessoires, la réparation et l'entretien de l'équipement doivent de l'ouverture murale pour empêcher l'isolation d'entrer en contact être faits seulement par une agence qualifiée.
  • Page 26 MINIMUM 4" (10.16cm) MINIMUM 4" (10.16cm) AUX MATÉRIAUX AUX MATÉRIAUX COMBUSTIBLES COMBUSTIBLES GUIDE VUE DE GUIDE VUE DE DESSUS DESSUS CAPUCHON D’ÉVENT PAS REPRÉSENTÉ MINIMUM DE 18" (45.7cm) AUX MATÉRIAUX COMBUSTIBLES GUIDE (IDENTIQUE À L'AUTRE CÔTÉ) APPAREIL NE PEUT SI REGISTRES DE PAS ÊTRE ENCASTRÉ...
  • Page 27 Emplacement de l'Alimentation Électrique 2. Attacher le tuyau d’échappement de 4" (10.16cm) de diamètre Sur le bas des panneaux des côtés gauche et droit, il y a une entrée sur le collet de la sortie d’échappement qui est sur la chambre défonçable de 7/8"...
  • Page 28 CALFEUTRER 4. Appliquer du ciment pour radiateur au collet de la sortie CALFEUTRER d’échappement de 4" (10.16cm) de diamètre et sur le collet de 4" PLAQUE EX- PLAQUE EX- TÉRIEURE DE (10.16cm) de diamètre du capuchon d’évent. Attacher le tuyau de TÉRIEURE DE MONTAGE MONTAGE...
  • Page 29 BONDE NPT DE 1/8" (3.175mm) POUR VÉRIFIER LE JAUGEAGE DES TUYAU D’ALIMENTATION VALVE VUE DE DESSUS CONNEXIONS. EN GAZ RÉGULATEUR DE PRESSION ÉVENT VALVE À PRISE POUR SORTIE DE CLÉ UNIVERSELLE VALVE DE FERMETURE PRESSION MANUELLE RACCORD HORIZONTAL ENTRÉE DE GAZ SORTIE DE GAZ ARRIVÉE PRISE POUR PRESSION...
  • Page 30 Pose des Fils Électriques AJUSTEMENT CONVENABLE DE LA FLAMME Si vous utilisez une source électrique extérieure, l’appareil, lorsqu’il est installé, doit avoir une prise de terre conforme avec les codes locaux ou dans l’absence de codes locaux, avec le National Electrical Code, ANSI/NFPA70 ou Canadian Electrical Code, CSA C22.1.
  • Page 31 POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil a une veilleuse qui doit être allumée manuel- •...
  • Page 32 SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN. APPELER UN TECHNICIEN D’ENTRETIEN GÉNÉRAL : Tous les radiateurs ont reçu un test d’allumage La veilleuse s’enflamme mais s’éteint lorsque le bouton est pour vérifier le bon fonctionnement. Ceci inclus la flamme du relâché: Suivre les instructions et appuyer sur le bouton plus long- brûleur principal, la flamme de la veilleuse, le fonctionnement temps et fermement.
  • Page 33 GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...
  • Page 34 S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro de Numéro Numéro de Description Description d’index la pièce d’index la pièce 11763 Dessus de la paroi extérieure Joint d’étanchéité...
  • Page 35 21 22 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623 45050-0-0523 Page 15...
  • Page 36 GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...