Terminals
Terminals
6.
Remove one clamp for fixing connecting hose to check plate holder.
Clamp
7.
Pull out hose for connecting water softener to sump assembly. And pull out pressure switch
hose.
Part name: 1 – connecting hose (water softener)
2 – Pressure switch hose
8.
Take up sump assembly, and pull out that from motor vibration-proof pad.
Part name: 1 – motor vibration-proof pad
6. Reverse the above procedure to install. And check out all connectors connects well.

Drain pump assembly

Removal and replacement
1.
Take out sump assembly. (see sump assembly removal
and installation)
2.
Remove all screws for fixing drain pump assembly. And
contrarotate the drain pump assembly to take out that.