To Install The Outdoor Unit - Daikin Altherma EHVH/X04S18CB Installer's Reference Manual

Low temperature split
Table of Contents

Advertisement

b
(mm)
a
Maximum snowfall height
b
EKFT008CA option kit
If the unit is installed on brackets to the wall, it is recommended to
use the EKFT008CA option kit and to install the unit as follows:
b
(mm)
a
Maximum snowfall height
b
EKFT008CA option kit
ERLQ004~008CA + EHVH/X04+08S18+26CB
Daikin Altherma – Low temperature split
4P384973-1D – 2018.07
INFORMATION
If you install the U-beams in combination with the low
sound cover (EKLN08A1), different installation instructions
apply for the U-beams. See the installation manual of the
low sound cover.
a
a Low sound cover
b Bottom parts of the low sound cover
c U-beams
7.3.4

To install the outdoor unit

CAUTION
Do NOT remove the protective cardboard before the unit is
installed properly.
1 Lift the outdoor unit as described in
accessories from the outdoor unit" on
2 Install the outdoor unit as follows:
7 Installation
c
b
"3.2.2  To remove the
page 8.
Installer reference guide
31