Gas Types - Winterwarm DXE80 Installation Manual

Table of Contents

Advertisement

3.2. Gas types

3.2.1.
Natural gas G20
Specification
Nominal supply pressure
Supply pressure (min. - max.)
Gas category
Class
Specification
Gas consumption (max.)
Burner injectors
Burner pressure high
Burner pressure low
CO
High (indication)
2
3.2.2. Propane
Specification
Nominal supply pressure
Supply pressure (min. - max.)
Gas category
Class
Specification
Gas consumption (max.)
Burner injectors
Burner pressure high
Burner pressure low
CO
High (indication)
2
6
Unit
Natural gas G20
mbar
20
mbar
17-25
-
II
H
P B/P
2
3
NL: II
EK
B/P
2
3
DE: II
ELL
B/P
2
3
BE: I
E(s), I
Er
2
2
FR: II
Er
B/P
2
3
PL: II
ELwLs
B/P
2
3
-
B22, C12, C32
Unit
DXE80
m
/h
8.8
3
n x Ømm
6x 3.7
mbar
7.4
mbar
3.2
%
8.3
Unit
Propane G31 (P)
mbar
30-50
mbar
25-50
-
II
H
P B/P
2
3
NL: II
EK
B/P
2
3
DE: II
ELL
B/P
2
3
BE: I
P
3
FR: II
Er
P
2
3
PL: II
ELwLs
B/P
2
3
-
B22, C12, C32
Unit
DXE80
m
/h
6.6
3
n x Ømm
6x 2.3
mbar
19.5
mbar
8.1
%
9.2
DXE100
11.4
8x 3.7
7.7
3.5
8.3
DXE100
8.6
8x 2.3
18.5
8.5
9.5