Clean Up & Maintenance; Step One: Clean Up Instructions; Step Two: Clean Up Instructions For The Spray Tip; Maintenance - Homeright FINISH MAX C800766 Manual

Paint sprayer hvlp electric spray gun, 1 nozzle sprays all, superior brass tip, 3 spray patterns
Hide thumbs Also See for FINISH MAX C800766:
Table of Contents

Advertisement

Available languages

Available languages

NOTE: For easier and faster cleaning, consider purchasing the Rapid Clean Kit (C900042.M)

STEP ONE: CLEAN UP INSTRUCTIONS

NOTE: Proper clean up is essential to keep your sprayer in optimum working condition.
Dried by-products act like glue and will cause moving parts to stick. Failure to properly clean
your paint sprayer will damage the unit. Taking the time to clean your sprayer immediately after
use will help your sprayer last longer and work correctly. If you are finished with the project or
are not going to use the sprayer within the day, you must follow these instructions for proper
clean up. Never store the sprayer longer than 30 minutes without cleaning.
1. Unplug sprayer from electrical outlet and pull trigger on spray gun so material inside unit
flows back into the container.
2. Empty any remaining (stain or paint) material from the container.
3. Fill container approximately 1/2 full with appropriate cleaning solution.
For latex, use warm soapy water; for oil-based, use a cleaning solution
recommended by the material manufacturer.
4. Plug sprayer into an electrical outlet.
5. Press the switch of the sprayer until the cleaning solution passes through the spray nozzle
for several seconds. (See Figure A.)
6. Remove container and properly discard the cleaning solution.
7. Unplug the sprayer from the electrical outlet.

STEP TWO: CLEAN UP INSTRUCTIONS FOR THE SPRAY TIP

Use the brush (included) to complete the following steps.
1. Unplug sprayer from electrical outlet and pull trigger on spray gun so material inside unit
flows back into the container.
2. Unscrew the container and discard any remaining cleaning solution.
3. Remove the pick-up tube from the sprayer and clean it with warm, soapy water.*
(See Figure B.)
4. Unscrew the air cap ring, remove the winged spray cap and the inner spacer.
Clean all three with warm, soapy water.* (See Figure C.)
5. Clean the sealing ring found between the container and the housing with warm,
soapy water*.
6. Clean the Brass Fluid Nozzle housing and the unit with warm, soapy water.* Remove
the Brass Fluid Nozzle by unscrewing and clean around the brass needle with the brush
provided. (See Figure D.)
7. Remove foam splash guard. Clean holes on each side of pickup tube with the tip of the
supplied brush. (See Figure E.)
8. Let the components dry thoroughly and reassemble the unit.
9. Store the unit.
* If you've been using oil-based liquids, clean these parts with whatever the liquid manufacturer recommends
(probably mineral spirits).

MAINTENANCE

Air filters should be inspected periodically. If it is excessively dirty, follow these steps
to remove and replace: (Figure F.)
1. Keeping the sprayer upright at all times, remove two screws from the motor lid
and remove the lid.
2. Replace filters (P/N C800982) and reinstall lid.
SERVICING A DOUBLE-INSULATED PRODUCT
In a double-insulated product, two systems of insulation are provided instead of grounding. No
grounding means is provided on a double insulated product, nor should a means of grounding
be added to the product. Servicing of a double-insulated product requires extreme care and
knowledge of the system and should only be done by qualified service personnel. Replacement
parts for a double-insulated product must be identical to those parts in the product.
CLEAN UP & MAINTENANCE
FINISH MAX
FINE FINISH SPRAYER
®
(C800766, C900076)
8
A
B
C
D
E
Holes
to clean
F
ENGLISH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Finish max c900076

Table of Contents