DO NOT ALLOW SPRAYED MATERIAL TO DRY IN SPRAY GUN,
ALWAYS CLEAN WITHIN 30 MINUTES OF USE
Proper clean up is essential to keep your sprayer in optimum working condition. Dried by-products will
act like glue and cause moving parts to stick or holes to plug. Failure to properly clean your sprayer will
damage the unit. Take the time to clean your sprayer immediately after each use.
Run cleaning solution through unit
1. Unplug the sprayer from electrical outlet. Pull trigger on spray gun, hold trigger down for a few
seconds, this allows material inside unit to flow back into container.
2. Empty any remaining material from container (see figure A).
3. Fill container with a small amount of cleaning solution.
MATERIAL
Latex
Oil-Based
4. Plug Sprayer into an electrical outlet. Turn Turbine on.
5. Spray cleaning solution and run solution through unit until clean (see figure B).
6. Unplug the sprayer from electrical outlet.
7. Remove container and properly discard any remaining cleaning solution.
Clean all removable Spray Gun Components in warm soapy water (see figures C & D).
8. Container
9. Pick-up tube
10. Air Cap and Nut
11. Paint Cup Gasket found in the spray gun cap
12. Spray tip. Unscrew and remove the air cap and nut. Use an 17 mm wrench or socket to unscrew
the Brass Fluid Nozzle. (use a counterclockwise motion)
Clean the Spray gun housing, brass fluid nozzle and fluid needle housing in warm soapy water
before reassembly
13. Use the brush provided to clean housing around needle (see figure E).
14. Thoroughly clean needle
15. There are two air holes deeply seated in the pick-up tube housing. (see figure F). Inspect holes
after the housing has been cleaned. If holes are clogged, it may be necessary to use a long piece
of straightened wire (a paperclip is ideal) to remove debris, be careful not to enlarge holes.
Reassemble
16. Make sure all components are thoroughly dried.
17. Place a drop of oil on the shank of the needle between the trigger and the front of the gun.
18. Insert brass fluid nozzle. Place air cup and screw on air nut.
19. Install pick up tube.
20. Inspect Paint Cup Gasket to ensure it is undamaged and then insert into cup.
21. Screw on container.
CLEAN UP & MAINTENANCE
CLEANING SOLUTION
Warm soapy water
Use manufacturer's recommendation
FINISH MAX PRO FINE FINISH SPRAYER
(C800850)
9
A
B
1
C
D
E
Brass
Fluid
Needle
Nozzle
Assembly
F