Installation - Gardner Denver RNC100 Instruction Manual

Refrigerated type compressed air dryers
Hide thumbs Also See for RNC100:
Table of Contents

Advertisement

IMPORTANT:
READ PRIOR TO STARTING THIS EQUIPMENT

1.0 INSTALLATION

1.1 Location
A.
For typical placement in a compressed air system, see
drawing.
B.
Air compressor intake–Locate air compressor so that
contaminants potentially harmful to the dryer (e.g.
ammonia) are not drawn into the air system.
C.
Dryer should be installed in a moderately heated, well
ventilated area. Avoid locations immediately adjacent
to cold exterior windows or walls, or adjacent to high
temperature ovens or boilers.
D.
Clearances: Minimum requirements for free air flow and
service access
Front 36 inches (914 mm)
Back 6 inches (152 mm)
Sides 36 inches (914 mm)
E.
Standard units are designed to operate in ambients:
Air-cooled: 40 to 110°F (4 to 43°C).
Water-cooled: 40 to 130°F (4 to 54°C).
F.
Installations in altitudes above 4500 feet (1370 meters) –
Dryer is adjusted to operate in altitudes up to 4500 feet
(1370 meters). If dryer is installed in an altitude above
this, and has not been preset at the factory for this
altitude, contact manufacturer's Service Department.
G.
The installation of a flexible connection prior to the
dryer is recommended to prevent possible damage from
vibration.
NOTE: Outdoor installation–Standard units are designed
for in door installation. Contact manufacturer if installing
outdoors.
1.2 Mounting
Mount the dryer on a level solid surface. Holes are provided in
the dryer base to permanently mount the dryer to the floor.
Aftercooler
Compressor
Dryer
Oil Removal
Separator
Filter
Control Panel
Moisture Separator
Coalescing Filter
(Option)
Float Drain
(Standard)
Control Panel
Moisture Separator
Electric Time Drain
with 3-Way Valve
(Standard)
Coalescing Filter
(Option)
RNC125 & RNC150
Control Panel
Moisture Separator
Coalescing Filter
(Option)
3-Way Drain Valve
Solenoid Valve
RNC200, RNC250, RNC300, RNC400, RNC500, RNC600, & RNC750
Air Inlet
Air Outlet
Electrical Entry
Drain Outlet
Condensor
Model
RNC100
Air Inlet
Air Outlet
Electrical Entry
(230VAC)
Drain Outlet
Condenser
Models
Electrical Entry
Air Inlet
Air Outlet
RS 232 Entry
Condenser
Drain Outlet
Models
(230 VAC)
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents