Magnetic MPT 353 Manual

Magnetic MPT 353 Manual

Full height turnstile mgc control unit
Hide thumbs Also See for MPT 353:
Table of Contents

Advertisement

Quick Links

Description
Full Height Turnstile
MPT-333 and MPT 353
MGC Control Unit
Doc. ID: 5817,0027EN
Version 01

Advertisement

Table of Contents
loading

Summary of Contents for Magnetic MPT 353

  • Page 1 Description Full Height Turnstile MPT-333 and MPT 353 MGC Control Unit Doc. ID: 5817,0027EN Version 01...
  • Page 2 MGC Control Unit MAGNETIC AUTOCONTROL GMBH Grienmatt 20 79650 Schopfheim Deutschland Telefon +49 7622 695 5 Fax +49 7622 695 802 info@magnetic-germany.com www.magnetic-access.com...
  • Page 3: Table Of Contents

    MGC Control Unit Contents Contents Notes on the document Purpose and contents of this description Symbols and illustrations used in this document 1.2.1 Warning notes and notes Target group 1.3.1 Personnel – activities and qualifications Digital inputs, digital outputs and relay outputs Digital inputs Digital outputs and relay outputs Digital power outputs of the MFM01 plug-in modules...
  • Page 4 MGC Control Unit Contents Menu “In-/Outputs” 4.3.1 Inputs 4.3.2 Outputs Menu “Service” 4.4.1 Gate HW 4.4.2 Further parameters Menu “System” Menu “Passage counter” Menu “Information” Menu “Factory settings” Function description Versions and definitions 5.1.1 Defintions and version MPT-353 Function sequence Start-up and regular movement sequence Operation modes 5.4.1...
  • Page 5: Notes On The Document

    MGC Control Unit Notes on the document Notes on the document Purpose and contents of this description This document describes the MGC control unit from the program versions listed below. Software number (Software #) and software version (SW version) are displayed in the menu “Module info”.
  • Page 6: Symbols And Illustrations Used In This Document

    MGC Control Unit Notes on the document Symbols and illustrations used in this document 1.2.1 Warning notes and notes Warning notes are characterised by pictograms in these operating instructions. A warning note starts with a signal word that expresses the extent of the hazard. It is absolutely essential to observe the warning notes and to proceed with caution in order to prevent accidents as well as bodily injuries and property damage.
  • Page 7: Target Group

    MGC Control Unit Notes on the document Target group 1.3.1 Personnel – activities and qualifications All work on the control unit may only be carried out by technicians and electricians with the following qualifications. Designation Qualification › Technician Has completed training as a plant mechanic, plant fitter, assembly mechanic, assembly fitter or has a comparable technical education.
  • Page 8: Digital Inputs, Digital Outputs And Relay Outputs

    MGC Control Unit Digital inputs, digital outputs and relay outputs Digital inputs, digital outputs and relay outputs WARNING Improper wiring and parameterisation of the control unit! Improper wiring and parameterisation of the control unit can lead to undesired functions and thus to injuries. ›...
  • Page 9 MGC Control Unit Digital inputs, digital outputs and relay outputs Clamp Function – Inputs that you assign this function "–" to are being deactivated. | Emergency open Emergency situation (Fail Safe) Connect fire service switches, emergency opening contacts, etc. to this input. This input has the highest priority.
  • Page 10: Digital Outputs And Relay Outputs

    MGC Control Unit Digital inputs, digital outputs and relay outputs Digital outputs and relay outputs Definition “Entry” and “Exit”: ä Page 38, Chapter 5.1. By parameterising the outputs, you assign certain functions to the outputs. If the function is marked with “|”, the output is inverted (Fail Safe). The following functions are assigned to the outputs as default settings.
  • Page 11 MGC Control Unit Digital inputs, digital outputs and relay outputs Function Function Passage free entry Control of display "Passage in zone controlled direction cleared" When the passage in the zone controlled direction is cleared, a permanent signal is emitted via this exit. This exit may also be used to block a pulse encoder such as a card reader for the opposite direction.
  • Page 12: Digital Power Outputs Of The Mfm01 Plug-In Modules

    MGC Control Unit Digital inputs, digital outputs and relay outputs Digital power outputs of the MFM01 plug-in modules The control unit is equipped with the plug-in module MFM01 with the function “Magnets for locking”. Furthermore, the control unit can be equipped with additional plug-in modules MFM01.
  • Page 13: Parameterising Control Unit

    MGC Control Unit Parameterising control unit Parameterising control unit Changing menu language The default setting in the MGC control unit is the menu language “English”. Change the menu language as follows: The operational view is displayed. FlowMotion MPT333 – – –...
  • Page 14 MGC Control Unit Parameterising control unit 4. Select the menu "System" with the two middle buttons « », « ». Main menu Settings In-/Outputs Service System Fig. 5: View "Main menu – System" 5. Confirm selection with the right control button « ». The following view is displayed.
  • Page 15 MGC Control Unit Parameterising control unit 8. Use the right button « » to select the new menu language. Your selection is marked with the symbol « ». Language German English French Fig. 9: View "Language – German, step 2" 9.
  • Page 16: Entering Password

    MGC Control Unit Parameterising control unit Entering password You need to enter a password in the following cases: › You would like to change parameters in the control unit and the password protection was activated. › You would like to reset the parameters to factory settings. If a password is required, the following view is displayed: Password –...
  • Page 17: Control Unit Elements

    MGC Control Unit Parameterising control unit 6. Use the right button « » to select the fourth digit of the password. The following view is displayed: Password Fig. 14: View "Enter fourth digit of the password" 7. Use the two middle buttons « », «...
  • Page 18: Displays Of The Control Unit

    MGC Control Unit Parameterising control unit Displays of the control unit FlowMotion MPT333 – – – – Fig. 16: Example "Operational view" Type pedestrian gate here MPT-333 electromotive Status display, here ready for operation Angle of rotation, here 0 Current function of the right control button, here calling menu "Main menu" Validations exit, here locked Hold-open time exit, here locked Operating display, here passage direction left enabled...
  • Page 19: Symbols In The Display

    MGC Control Unit Parameterising control unit Symbols in the display 3.5.1 Control button functions The control unit is equipped with 4 control buttons. The function of the control buttons change depending on the current view in the display. The current functions are shown in the display.
  • Page 20: Further Symbols

    MGC Control Unit Parameterising control unit 3.5.2 Further symbols Clamp Description Wrong password entered. Access denied. Reset values to factory settings. To do this, you must enter the password "0000". The next validation is blocked by the random function. There is information. Check the "Information" menu. To do this, press the left operating button.
  • Page 21: Protecting Parameterisation From Access

    MGC Control Unit Parameterising control unit Protecting parameterisation from access You can apply the access to the main menu with password protection. ä Page 34, Chapter 4.4.2. Parameterise value Example: Change hold-open time The operational view is displayed. ä ä Page 18, Fig. 16. 1.
  • Page 22: Switching The "Service" Mode On And Off

    MGC Control Unit Parameterising control unit Switching the “Service” mode on and off In service mode, all opening signals are ignored. Switch on mode “Service” Switch the “Service” switch for the “Service” mode. The LED lights red. The display backlighting flashes. Switch off mode “Service”...
  • Page 23: Description Of Menus And Parameters

    MGC Control Unit Description of menus and parameters Description of menus and parameters Menu “Information” Call and navigate The operational view is displayed. ä Page 13, Fig. 2. 1. Press left button « ». 2. Use the left button « » to scroll within the menu. 3.
  • Page 24: Menu "Settings

    MGC Control Unit Description of menus and parameters Menu “Settings” 4.2.1 Hold-open time Operational view > Main menu > Settings > Hold-open time Parameter Description Hold-open time Set the hold-open time. The hold-open time is started by an opening pulse by a control device, such as a card reader.
  • Page 25: Interlock

    MGC Control Unit Description of menus and parameters 4.2.3 Interlock Operational view > Main menu > Settings > Interlock Parameter Description Interlock Activate and deactivate the "Interlock" function. If the interlock has been activated, further rotation of the centre pillar is blocked for 1 second after each pass.
  • Page 26: Vend Count

    MGC Control Unit Description of menus and parameters 4.2.4 Vend count Operational view > Main menu > Settings > Vend count Parameter Description Entry Shows the current counter for validations for the passages in zone controlled direction. Exit Displays the current counter for validations of passages in the zone not controlled direction.
  • Page 27 MGC Control Unit Description of menus and parameters Operational view > Main menu > Settings > Signalling Parameter Description GED mode entry Set the behaviour of the optional GEDs. Options › Off: The display is dark. › Red: The display is permanently red. ›...
  • Page 28: Random Check Function

    MGC Control Unit Description of menus and parameters 4.2.6 Random check function The MGC control unit is equipped with the “Random check function” option. This function allows random bag and identity control of persons. If a hit was generated by the random function and the next validation is blocked by the random function, the following symbol appears on the display of the control unit: «...
  • Page 29 MGC Control Unit Description of menus and parameters Operational view > Main menu > Settings > Random check function Parameter Description Hit range The function depends on the selected mode. For the "Counting" mode, use this parameter to set the value at which a hit is to be generated.
  • Page 30: Menu "In-/Outputs

    MGC Control Unit Description of menus and parameters Operational view > Main menu > Settings > Random check function Parameter Description Direction Select the passage direction for which the random hits are to be generated. Options › Both: Random hits occur in both passage directions. With this option, validations are not deleted.
  • Page 31: Menu "Service

    MGC Control Unit Description of menus and parameters Menu “Service” 4.4.1 Gate HW IMPORTANT! By default, the pedestrian gate is delivered with the configuration "Locking normally open". If you want a different configuration, convert the locking and adjust the parameters "Invert magnet RL1" and "Invert magnet RL2".
  • Page 32 MGC Control Unit Description of menus and parameters Operational view > Main menu > Service > Gate HW Parameter Description Exit direction MPT-333: Unless otherwise ordered, the turnstile is delivered for the "Entrance side right" design. The control unit is parameterised accordingly. MPT-353: Unless otherwise ordered, both passages of the turnstile are delivered for the “Entrance side right”...
  • Page 33 MGC Control Unit Description of menus and parameters Installation version magnets and settings MGC The following installation versions are possible for the magnets RL1 and RL2. The settings for the parameters “Invert RL1” and “Invert RL2” depend on the installation version.
  • Page 34: Further Parameters

    MGC Control Unit Description of menus and parameters 4.4.2 Further parameters Operating view > Main menu > Service Parameter Description Cycles Display of complete passage procedures. Lifetime Display operating hours counter. The operating hours counter records the time, during which the pedestrian gate is supplied with electrical power. System time Displays the internal date and the internal clock.
  • Page 35: Menu "Passage Counter

    MGC Control Unit Description of menus and parameters Menu “Passage counter” Operational view > Main menu > Passage counter Parameter Description From entry Display for the number of completed passages in zone controlled direction. If necessary, the value can be changed. Setting range ›...
  • Page 36: Menu "Factory Settings

    MGC Control Unit Description of menus and parameters Menu “Factory settings” IMPORTANT! The parameters of the control unit are stored in the three memory areas "Default settings", "Factory settings" and "User settings". The default settings are identical to the factory settings in these operating instructions.
  • Page 37 MGC Control Unit Description of menus and parameters 6. Press the right button « ». √ The safety prompt “Save changes?” appears. › If the changes are to be saved, press the right button « ». The current settings are reset to factory settings. A restart is performed. ›...
  • Page 38: Function Description

    MGC Control Unit Function description Function description Versions and definitions Left and right › Left: The passage is to the left of the locking comb. › Right: The passage is to the right of the locking comb. Entry and exit The service door or the cover of the support beam points into the zone controlled.
  • Page 39 MGC Control Unit Function description Version “Entrance side left” Entry Exit Fig. 22: Version "Entrance side left" Fig. 23: Version "Entrance side left" – – view from the zone not view from the zone controlled controlled (ZNC), the entrance is (ZC), the exit is to the right of to the left of the locking comb the locking comb...
  • Page 40: Defintions And Version Mpt-353

    MGC Control Unit Function description 5.1.1 Defintions and version MPT-353 Left and right › Left: The passage is to the left of the locking comb. › Right: The passage is to the right of the locking comb. Version IMPORTANT! Unless otherwise ordered, both passages of the turnstile are delivered with "Entrance side right"...
  • Page 41 MGC Control Unit Function description Fig. 25: View from the zone not controlled (ZNC)
  • Page 42: Function Sequence

    MGC Control Unit Function description Function sequence Start The control unit receives an opening impulse. The free and the blocked directions can be signalled Passage is possible. via optional displays. The hold-open time is started. While the hold-open time is running, passage is possible. The centre pillar remains Has the in the end position.
  • Page 43: Start-Up And Regular Movement Sequence

    MGC Control Unit Function description Start-up and regular movement sequence Power-off state As standard, the pedestrian gate is supplied with the “Locking normally open” configuration. In this case, the turnstile can be passed in both directions in the de- energised state. The centre pillar can be turned freely. If the pedestrian gate is supplied with the configuration “Locking normally closed”, the turnstile is locked in both directions.
  • Page 44: Pulse Operation In Both Directions With Vend Count

    MGC Control Unit Function description 5.4.2 Pulse operation in both directions with vend count This operating mode works similarly to pulse operation without vend count. The pulse must be present between 0.2 and 1 sec. In this operating mode, pulses for both passage directions can be stored and processed one after the other.
  • Page 45: Emergency

    MGC Control Unit Function description Emergency The turnstile is available in the following configurations: › Locking normally open › Locking normally closed If no details were given in the order, the configuration “Locking normally open” is supplied. If a conversion is necessary, the locking must be converted and the parameters adjusted.
  • Page 46: Corrective Action

    MGC Control Unit Corrective action Corrective action Safety in troubleshooting Qualification of personnel › Technician › Electrical specialist ä Page 7, Chapter 1.3.1. Personal protective equipment Wear the following personal protective equipment: › Work clothes › Protective gloves › Safety shoes ›...
  • Page 47: Malfunctions Turnstile

    MGC Control Unit Corrective action Malfunctions turnstile Malfunction: Display is difficult or impossible to read. Possible cause Corrective action Removal by Display contact set too light or Correct display contact. ä Page Technician dark. 20, Chapter 3.6. Malfunction: Centre pillar does not rotate. Possible cause Corrective action Removal by...
  • Page 48: Event, Warning And Error Messages - Logic Control (Control Unit)

    MGC Control Unit Corrective action Error messages “ERROR” Faults that cannot be reset by the control unit are displayed as errors. The pedestrian gate is put out of service. If the function “Error” has been chosen for an output, this output is deactivated at pending errors (fail safe).
  • Page 49: Event, Warning And Error Messages - All Modules

    MGC Control Unit Corrective action Number Designation Possible cause Corrective action › FF21 Max. pulse without The set maximum number Check card reader / passage of pulses without passage validation device, e.g. WARNING has been reached. card reader. › Check the "Max imp. w/o passage"...
  • Page 50: Menu Setup

    MGC Control Unit Menu setup Menu setup FlowMotion MPT333 – – – – Error, Warning, Main menu Event Inputs Settings Outputs In-/Outputs Modul info Service System Passage counter Information Factory settings Fig. 26: Menu "Information" and "Main menu" Main menu Settings Hold-open time Permanent open...
  • Page 51 MGC Control Unit Menu setup Main menu Settings In-/Outputs Inputs Digital inputs 1 – 8 Outputs Digital outputs 1 – 4 Relay outputs 1 – 6 Service Gate HW Invert Magnet RL1 Invert Magnet RL2 Exit direction Cycles Lifetime System time Main menu password System Language...
  • Page 52 MGC Control Unit...
  • Page 53: Index

    MGC Control Unit Index Index Function sequence ........42 Symbole Gate HW ............31 | Emergency open ......... 9 Gate ready ........... 10 | Error ............10 GED green entry .......... 11 | Over-climb detection ........9 GED green exit ..........11 | Warning ............
  • Page 54 MGC Control Unit Index Mode “Service “ .......... 22 Serial no............35 Module info ..........23 Service Menu ............31 Mode ............22 Notices Service mode active ........11 Presentation ..........6 Settings ............24 Signalling ............. 26 Software # ........... 35 Open entry ............
  • Page 55 MGC Control Unit...
  • Page 56 MAGNETIC AUTOCONTROL GMBH Vertriebspartner Grienmatt 20 79650 Schopfheim Deutschland Telefon +49 7622 695 5 Fax +49 7622 695 802 info@magnetic-germany.com www.magnetic-access.com F10044506...

This manual is also suitable for:

Mpt-333

Table of Contents