Personal protective equipment Symbols on the device For your safety To protect the environment Emergency opening of the pedestrian gate Technical data Dimensions and design MPT-333 Dimensions and design MPT-353 Electrical connection Operating conditions Emissions Control unit MGC Design and function...
Page 4
MPT-333 and MPT-353 Contents Receipt of goods, transport and storage Goods receiving department Safety during transport Transport Storage Unpacking, scope of delivery and identification Unpacking Scope of delivery Identification 6.3.1 Type plate Mounting the MPT-333 Safety during mounting Mounting options...
Page 5
MPT-333 and MPT-353 Contents Required steps Specifying the installation position Setting up foundation and placing empty conduits 8.5.1 Requirements foundation 8.5.2 Requirements empty conduits 8.5.3 Setting up foundation and placing empty conduits 8.5.4 Foundation and empty conduit plan for base frame FURA T5 8.5.5...
Page 6
MPT-333 and MPT-353 Contents Operation Cleaning and maintenance 13.1 Safety during cleaning and maintenance 13.2 Cleaning the pedestrian gate 13.2.1 Cleaning the pedestrian gate from the outside 13.2.2 Cleaning support beam from the inside 13.3 Maintenance schedule Corrective action Spare parts and repair 15.1...
IMPORTANT! For the parameterisation of the MGC control unit see separate document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)". Read and store the operating instructions Pre-requisite for safe working is the observance of all specified safety notes, warning notes and instructions.
MPT-333 and MPT-353 Notes on the document Non-compliance with the operating instructions Magnetic declines all liability for personal injury and material damage caused by not observing the operating instructions. This applies in particular to damage caused by: › Non-intended use ›...
Page 9
MPT-333 and MPT-353 Notes on the document CAUTION The signal word CAUTION points to a potentially dangerous situation, which can lead to minor injuries if it is not avoided. NOTICE The signal word NOTICE points to a potentially harmful situation, which leads to property damage if it is not avoided.
The turnstile may only be operated within the temperature range indicated on the type plate. Misapplications Any other or further use is considered improper use. Magnetic is not liable for any resulting personal injury or damage to property. For example, the following applications are considered to be contrary to regulations: ›...
MPT-333 and MPT-353 Safety Target groups 2.3.1 Operator and his responsibilities The operator must comply with the statutory obligations regarding work safety. In addition to the safety instructions and warning notes in these operating instructions, the valid safety, accident prevention and environmental protection regulations must be observed.
MPT-333 and MPT-353 Safety 2.3.2 Personnel - activities and qualifications Only authorised, trained and sufficiently qualified personnel may work on and with the product. The personnel must know and understand the operating instructions and the required operating instructions. Designation Qualification ›...
MPT-333 and MPT-353 Safety Symbols on the device Warning of dangerous electrical voltage! The warning sign indicates hazardous areas with dangerous electrical voltage. Non-observance of the warning signs causes severe injuries or death. The work to be carried out may only be carried out by a qualified electrician or an electric safety expert.
MPT-333 and MPT-353 Safety To protect the environment Improper disposal! Improper disposal can lead to damage to the environment. › Dispose of product in accordance with local and national laws and regulations. › Sort resources and supply them to recycling.
MPT-333 and MPT-353 Technical data Technical data Dimensions and design MPT-333 1510 102.5 1424 1500 Fig. 1: Dimensions MPT-333 – front view (dimensions in mm), shown here version "entrance side left", illumination optional...
Page 17
MPT-333 and MPT-353 Technical data Fig. 2: Dimensions MPT-333 – side view (dimensions in mm), illumination optional ∅ 16 ∅ 35 Fig. 3: Dimensions MPT-333 – view from below (dimensions in mm), illumination optional...
Page 18
1510 mm x 1288 mm x 2235 mm attachments (width x depth x height) › Weight Turnstile without attachments: 325 kg › Base frame: 63 kg Material Hot-dip galvanised steel › Colour Hot-dip galvanised › Service door: Powder-coated RAL 7042 Table 3: Dimensions and design – MPT-333...
MPT-333 and MPT-353 Technical data Dimensions and design MPT-353 2210 1062 2124 2200 Fig. 4: Dimensions MPT-353 – front view (dimensions in mm), illumination optional...
Page 20
MPT-333 and MPT-353 Technical data 1030 1238 1280 1318 Fig. 5: Dimensions MPT-353 – side view (dimensions in mm), illumination optional...
Page 21
MPT-333 and MPT-353 Technical data 1515 Ø 50 757.5 1062 Fig. 6: Dimensions MPT-353 – view from below (dimensions in mm), illumination optional Designation Value Dimensions without 2210 mm x 1318 mm x 2235 mm attachments (width x depth x height) ›...
5.5 kW 1.1 kW during switch-on Duty cycle 100 % Table 5: Electrical connection – MPT-333 Designation Value 230 V AC / 50 Hz 120 V AC / 60 Hz Power supply 100 to 240 V AC ± 10 %, 50 to 60 Hz ›...
Storage temperature range –30 to +55 °C Relative humidity Max. 95 %, non-condensing IP rating IP 43, optional: IP 54 Table 7: Operating conditions – MPT-333 and MPT-353 Emissions Designation Value Airborne sound pressure level ≤ 70 dB (A) (LpA) Table 8: Emissions –...
MPT-333 and MPT-353 Technical data Control unit MGC The MPT-333 turnstile contains a control unit. The MPT-353 turnstile contains two control units. The specifications are per control unit. Designation Value Power supply 24 V DC Control unit max. 1 A max. 300 mA +...
MPT-333 and MPT-353 Design and function Design and function Design MPT-333 Fig. 7: Design "Full Height Turnstile MPT-333" Cage half Mounting the bracket for optional attachment control devices Floor bearing Centre pillar Locking comb Support beam with drive unit and drive flange...
MPT-333 and MPT-353 Design and function Design MPT-353 Fig. 8: Design "Full Height Turnstile MPT-353" Cage half (2 pieces) Mounting the bracket for optional attachment control devices Floor bearing (2 pieces) Centre pillar, with different layout of the U-brackets Locking comb, with different layout of the U-brackets...
MPT-333 and MPT-353 Design and function Function The MPT turnstile is used to control pedestrians in outdoor areas with relatively high safety requirements. The turnstile can be operated either in one direction or in both directions. Normally, the turnstile is closed. Only after authorisation by means of an external command unit, such as a card reader, will a passage be possible and the centre pillar can be rotated by 120°.
MPT-333 and MPT-353 Design and function Definitions and versions 4.4.1 Definitions and versions MPT-333 Left and right › Left: The passage is to the left of the locking comb. › Right: The passage is to the right of the locking comb.
Page 29
MPT-333 and MPT-353 Design and function Version "Entrance side left" Entry Exit Fig. 11: Version "Entrance side left" Fig. 12: Version "Entrance side left" – – view from the zone not view from the zone controlled controlled (ZNC), the entrance...
MPT-333 and MPT-353 Design and function 4.4.2 Defintions and version MPT-353 Left and right › Left: The passage is to the left of the locking comb. › Right: The passage is to the right of the locking comb. Version IMPORTANT! Unless otherwise ordered, both passages of the turnstile are delivered with “Entrance side right”...
Page 31
MPT-333 and MPT-353 Design and function Fig. 14: View from the zone not controlled (ZNC)
MPT-333 and MPT-353 Receipt of goods, transport and storage Receipt of goods, transport and storage Goods receiving department Immediately check the delivery after receipt for completeness and transport damages. In the event of externally visible transport damage, proceed as follows: ›...
MPT-333 and MPT-353 Receipt of goods, transport and storage WARNING Lifting of heavy loads! The weight of heavy objects can severely injure a person's back or supportive system. › Preferably transport the transported goods with suitable transport aids. › Alternatively, the transported goods can be carried by two persons.
MPT-333 and MPT-353 Receipt of goods, transport and storage Storage Store packages or the product under the following conditions: › Store the delivery in its original packaging. Observe the symbols on the packaging. › Do not store outdoors. › Store dry and dust free.
1. Unpack product at final location. 2. Report incomplete and faulty delivery to Magnetic. 3. Check the scope of delivery with the delivery note. 4. Separate material according to type and size and continue to use them after...
MPT-333 and MPT-353 Unpacking, scope of delivery and identification Scope of delivery For options and attachments, see your order confirmation. MPT-333 The following components are supplied as standard for each MPT-333 turnstile: › 1 centre pillar › 1 cage half ›...
MPT-333 and MPT-353 Unpacking, scope of delivery and identification Identification 6.3.1 Type plate The type plate is located under the cover to the right of the drive unit. MAGNETIC AUTOCONTROL GmbH D-79650 Schopfheim Ser.-Nr. Made in Germany Fig. 15: Type plate MPT-333...
MPT-333 and MPT-353 Mounting the MPT-333 Mounting the MPT-333 Safety during mounting Qualification of personnel › Technician › Electrical specialist ä Page 12, Chapter 2.3.2. Personal protective equipment Wear the following personal protective equipment: › Work clothes › Protective gloves ›...
This version must be chosen for use on interlocking stone paving and cobblestones. Optionally, you can order an attachment set for mounting the base frame and an attachment set for mounting the turnstile on the base frame from Magnetic.
Install and connect access-control devices. ä Page 97, Chapter 10.7. Specifying the installation position The turnstile MPT-333 is available in the versions "Entrance side right" and "Entrance side left". ä Page 28, Chapter 4.4.1. The layout of the components depends on the version ordered. The service door in the support beam should point towards the zone controlled.
MPT-333 and MPT-353 Mounting the MPT-333 Foundation and empty conduit plan for base frame FURA T3: ä Page 43, Fig. 16 and ä Page 44, Fig. 17. Foundation and empty conduit plan for direct mounting: ä Page 45, Fig. 18 and ä Page 46, Fig. 19.
MPT-333 and MPT-353 Mounting the MPT-333 7.5.3 Setting up foundation and placing empty conduits 1. Excavate the foundation hole according to the foundation and empty conduit plan. 2. Place empty conduits according to the foundation and empty conduit plan in the foundation hole.
Page 43
MPT-333 and MPT-353 Mounting the MPT-333 7.5.4 Foundation and empty conduit plan for base frame FURA T3 1800 1612 1410 1257.5 1110 Fig. 16: Foundation and empty conduit plan for base frame FURA T3 – top view (dimensions in mm)
Page 44
MPT-333 and MPT-353 Mounting the MPT-333 Fig. 17: Foundation and empty conduit plan for base frame FURA T3 – side view (dimensions in mm) Finished paving such as interlocking stones or cobblestones, flush with the attachment plates Gravel and sand layer...
Foundation and empty conduit plan for direct mounting 1800 1424 Fig. 18: Foundation and empty conduit plan for direct mounting MPT-333 – top view (dimensions in mm) Foundation C35/45 XD3 XF2 with reinforcement, foundation depth: at least 800 mm, frost-proof F: Foundation anchors (7 pieces), bores for sleeves with inner thread depending on make: Upat UKA 3 M10: Drilling diameter 16 mm, drilling depth 90 mm;...
Page 46
MPT-333 and MPT-353 Mounting the MPT-333 Mag00897 Fig. 19: Foundation and empty conduit plan for direct mounting MPT-333 – side view (dimensions in mm) Foundation C35/45 XD3 XF2 with reinforcement, foundation depth: at least 800 mm, frost-proof Empty conduit: Lay empty conduits separately for mains cable and control lines. Allow empty conduits to protrude approx.
MPT-333 and MPT-353 Mounting the MPT-333 Assembling and mounting the base frame You need to install the pedestrian gate with a base frame on interlocking stone paving. Dimensions of foundation and base frame, position of foundation anchors, levelling screws and empty conduits: ä...
Page 48
MPT-333 and MPT-353 Mounting the MPT-333 min. 5 m Fig. 21: Assembling the base frame FURA T3 Base frame FURA T3 Borehole Anchor rod Hilti HIT-Z-R M10 x 160 A4 Washer Ø10.5 Washer Line e.g. mains cable...
MPT-333 and MPT-353 Mounting the MPT-333 Assembling the base frame IMPORTANT! The injection mortar is not included in the scope of delivery. We recommend the injection mortar Hilti HIT-HY 200-A for the Hilti anchor rods Hilti HIT-Z-R. Follow the separate instructions for the injection mortar and foundation anchors.
MPT-333 and MPT-353 Mounting the MPT-333 Mounting the MPT-333 The mounting of the turnstile on a base frame and the mounting of the turnstile directly on a foundation are identical in procedure. Only the attachment material is partly different. The following figures show the installation with the optional base frame.
MPT-333 and MPT-353 Mounting the MPT-333 3. Mount the cage half. Fig. 23: Mounting the cage half Cage half Hexagon head screw M10 x 30 Washer Ø10.5 7.8.2 Mounting the support beam 1. Loosen the screw of the cover. 2. Dismount the protective earth conductor at the cover.
Page 52
MPT-333 and MPT-353 Mounting the MPT-333 Fig. 24: Putting on the support beam and installing it Support beam Countersunk screw Nut M12 Toothed disc 10.5 for grounding the support beam Hexagon head screw M10 x 20 for grounding the support beam...
MPT-333 and MPT-353 Mounting the MPT-333 7.8.3 Mounting the centre pillar 1. Attach sleeve and washer with hexagon head screw. 2. Slide the plastic bearing over the sleeve, washer and hexagon head screw. Fig. 25: Mounting the floor bearing (plastic bearing, sleeve, washer and hexagon head...
Page 54
MPT-333 and MPT-353 Mounting the MPT-333 4. Fix the centre pillar to the drive flange from above using the four screws supplied. Make sure that the centre pillar is correctly positioned in relation to the locking unit. ä Page 56.
Page 55
MPT-333 and MPT-353 Mounting the MPT-333 Fixing the centre pillar to the floor bearing 5. Push the plastic bearing from below into the centre pillar until the plastic bearing is flush with the centre pillar. 6. Tighten all 3 headless screws such that the centre pillar can be moved easily in both rotating directions.
MPT-333 and MPT-353 Mounting the MPT-333 Correct positioning of the centre pillar IMPORTANT! Observe correct positioning. The countersink on the switching cam (item 1) must point forward into the zone controlled (ZC). The centre pillar must be mounted such that the bracket row (item 3), which is opposite to the countersink on the underside of the centre pillar flange (item 2), is in the locked position.
MPT-333 and MPT-353 Mounting the MPT-333 Checking the assembly After assembly, check the following points: › Are all foundation anchors firmly fixed? › Are all fastening screws firmly tightened? › Is the support beam earthed? ä Page 52, Fig. 24.
MPT-333 and MPT-353 Mounting the MPT-353 Mounting the MPT-353 Safety during mounting Qualification of personnel › Technician › Electrical specialist ä Page 12, Chapter 2.3.2. Personal protective equipment Wear the following personal protective equipment: › Work clothes › Protective gloves ›...
This version must be chosen for use on interlocking stone paving and cobblestones. Optionally, you can order an attachment set for mounting the base frame and an attachment set for mounting the turnstile on the base frame from Magnetic.
MPT-333 and MPT-353 Mounting the MPT-353 Required steps The following work steps must be carried out before mounting: › Specify the installation position. ä Page 60, Chapter 8.4. › Set up foundation and placing empty conduits. ä Page 60, Chapter 8.5.
MPT-333 and MPT-353 Mounting the MPT-353 Foundation and empty conduit plan for base frame FURA T5: ä Page 63, Fig. 28 and ä Page 64, Fig. 29. Foundation and empty conduit plan for direct mounting: ä Page 65, Fig. 30 and ä Page 66, Fig. 31.
MPT-333 and MPT-353 Mounting the MPT-353 8.5.3 Setting up foundation and placing empty conduits 1. Excavate the foundation hole according to the foundation and empty conduit plan. 2. Place empty conduits according to the foundation and empty conduit plan in the foundation hole.
Page 63
MPT-333 and MPT-353 Mounting the MPT-353 8.5.4 Foundation and empty conduit plan for base frame FURA T5 2500 2312 2110 1957.5 1810 1400 1250 1100 542.5 N LR Fig. 28: Foundation and empty conduit plan for base frame FURA T5 –...
Page 64
MPT-333 and MPT-353 Mounting the MPT-353 Fig. 29: Foundation and empty conduit plan for base frame FURA T5 – side view (dimensions in mm) Finished paving such as interlocking stones or cobblestones, flush with the attachment plates Gravel and sand layer...
MPT-333 and MPT-353 Mounting the MPT-353 8.5.5 Foundation and empty conduit plan for direct mounting 2500 1062 1062 Fig. 30: Foundation and empty conduit plan for direct mounting MPT-353 – top view (dimensions in mm) Foundation C35/45 XD3 XF2 with reinforcement, foundation depth: at least 800 mm,...
Page 66
MPT-333 and MPT-353 Mounting the MPT-353 Fig. 31: Foundation and empty conduit plan for direct mounting MPT-353 – top view (dimensions in mm) Foundation C35/45 XD3 XF2 with reinforcement, foundation depth: at least 800 mm, frost-proof Empty conduit: Lay empty conduits separately for mains cable and control lines. Allow empty conduits to protrude approx.
MPT-333 and MPT-353 Mounting the MPT-353 Mounting the base frame You need to mount the pedestrian gate with a base frame on interlocking stone paving. Dimensions of foundation and base frame, position of foundation anchors, levelling screws and empty conduits: ä...
Page 68
MPT-333 and MPT-353 Mounting the MPT-353 Mounting the base frame IMPORTANT! The injection mortar is not included in the scope of delivery. We recommend the injection mortar Hilti HIT-HY 200-A for the Hilti anchor rods Hilti HIT-Z-R. Follow the separate instructions for the injection mortar and foundation anchors.
MPT-333 and MPT-353 Mounting the MPT-353 Preliminary work for installation directly on the foundation Prerequisites › The conduits have been placed. › The foundation has cured. IMPORTANT! Observe the separate instructions as well as the packaging inscriptions for the attachment material.
MPT-333 and MPT-353 Mounting the MPT-353 8.8.1 Mounting the cage halves 1. Pull the mains cable and control lines through the support of the cage half. Alternatively, you can also pull the mains cable and control lines through the support of the cage half on the other side.
MPT-333 and MPT-353 Mounting the MPT-353 3. Mount the second cage half. Fig. 34: Mounting the second cage half Cage half Hexagon head screw M10 x 30 Washer Ø10.5 8.8.2 Mounting the support beam 1. Loosen the screw of the cover.
Page 72
MPT-333 and MPT-353 Mounting the MPT-353 4. Place support beam with lifting device on the cage halves. At the same time, pull the lines through the bores in the bottom of the support beam. WARNING Risk of injury from a falling support beam! 5.
MPT-333 and MPT-353 Mounting the MPT-353 8.8.3 Mounting the connecting rods and the centre pillars 1. Mount the connecting rod. Fig. 36: Mounting the connecting rod Connecting rod Screw M12 x 35 Nut M12...
Page 74
MPT-333 and MPT-353 Mounting the MPT-353 2. Mount both floor bearings. › Attach sleeve and washer with hexagon head screw. › Slide the plastic bearing over the sleeve, washer and hexagon head screw. Fig. 37: Mounting the floor bearing (plastic bearing, sleeve, washer and hexagon head...
Page 75
MPT-333 and MPT-353 Mounting the MPT-353 3. Place the centre pillar with heel guard on the floor bearing. Note the different designs of the two centre pillars. Attaching the centre pillar with heel guard to the drive flange 4. Fix the centre pillar to the drive flange from above using the four screws supplied.
Page 76
MPT-333 and MPT-353 Mounting the MPT-353 Fig. 38: Mounting centre pillar with heel guard Centre pillar with heel guard Floor bearing Threaded pin Flange Rubber buffer Washer Hexagon head screw, flange connection, secure with threadlocker such as Loctite 241. Countersink on the flange bottom of the centre pillar...
Page 77
MPT-333 and MPT-353 Mounting the MPT-353 8. Place the centre pillar without heel guard on the floor bearing. Fixing the centre pillar without heel guard to the drive flange 9. Fix the centre pillar to the drive flange from above using the four screws supplied.
Page 78
MPT-333 and MPT-353 Mounting the MPT-353 Fig. 39: Mounting the centre pillar without heel guard Centre pillar without heel guard Floor bearing Threaded pin Flange Rubber buffer Washer Hexagon head screw, flange connection, secure with threadlocker such as Loctite 241.
Page 79
MPT-333 and MPT-353 Mounting the MPT-353 Correct positioning of the centre pillars IMPORTANT! Observe correct positioning. The countersink on the switching cam (item 1) must point forward into the zone controlled (ZC). The centre pillar must be mounted such that the bracket row (item 3), which is opposite to the countersink on the underside of the centre pillar flange (item 2), is in the locked position.
MPT-333 and MPT-353 Mounting the MPT-353 8.8.4 Mounting the locking combs 1. Mount the first locking comb. Fig. 41: Mounting the first locking comb Locking comb Hexagon head screw M10 x 30 Washer Ø10.5...
MPT-333 and MPT-353 Mounting the MPT-353 2. Mount the second locking comb. Fig. 42: Mounting the second locking comb Locking comb Hexagon head screw M10 x 30 Washer Ø10.5 8.8.5 Closing the cover of the support beam When the installation work is completed or during extended breaks, close the support beam with the cover.
MPT-333 and MPT-353 Mounting the MPT-353 Checking the assembly After mounting, check the following points: › Are all foundation anchors firmly fixed? › Are all fastening screws firmly tightened? › Is the support beam earthed? ä Page 72, Fig. 35.
Magnetic offers the mounting pillar ASMP as attachment for the installation of access-control devices. The mounting of the optional mounting pillar is shown for the MPT-333 turnstile. For the MPT-353 turnstile, the mounting pillar is mounted in the same way. Four mounting pillars are required for the MPT-353 turnstile.
Page 84
Ø 10 Ø 10 Ø 30 Fig. 44: Required holes mounting pillar (all dimensions in mm) Standard height for implementation by Magnetic 2. Pull the pull wires or lines for the mounting pillar through the outer supports of the cage half.
Page 85
MPT-333 and MPT-353 Mounting the optional mounting pillar for access-control devices Installing the mounting pillar Fig. 45: Mounting pillar and attachment material...
Page 86
MPT-333 and MPT-353 Mounting the optional mounting pillar for access-control devices 1. Mount the U-profile to the outer support of the cage half. Fig. 46: Mounting the U-profile U-profile Outer support cage half Washers ø8.4 Spring washer A8 Hexagon head screw M8 x 30...
Page 87
MPT-333 and MPT-353 Mounting the optional mounting pillar for access-control devices 2. Mount the lower holder. Fig. 47: Mounting the lower holder Spring washer A6 Screw M6 x 16...
Page 88
MPT-333 and MPT-353 Mounting the optional mounting pillar for access-control devices 3. Mount the attachment angle to the mounting pillar. Tighten nut by hand. Fig. 48: Mounting the attachment angle Screw DIN 7991 M8 x 25 Sleeve Attachment angles Washer PE ø8.4 Washer ø8.4...
Page 89
MPT-333 and MPT-353 Mounting the optional mounting pillar for access-control devices 4. Mount the attachment angle with mounting pillar to the U-profile. Fig. 49: Mounting the attachment angle Spring washer A6 Screw M6 x 16 5. Align the mounting pillar by turning it.
Page 90
MPT-333 and MPT-353 Mounting the optional mounting pillar for access-control devices 6. Fix the mounting pillar to the lower holder. Fig. 51: Fixing the mounting pillar Nut M8 Spring washer A8 Washer ø8.4 Screw M8 x 25 7. Tighten the screw and nut on the upper attachment angle.
Protect yourself in buildings or vehicles. NOTICE Electromagnetic interference! The pedestrian gate is approved for industrial, residential, commercial and business use. Operation in other electro-magnetic environmental conditions may cause interference or malfunctions. › Place control lines and mains cables into separate conduits.
Electrical connection 10.3 Open and close cover or service door IMPORTANT! The hood for the MPT-333 turnstile is equipped with a service door. The hood for the MPT-353 turnstile is equipped with two service doors. Fig. 52: Open and close cover or service door...
3. Secure the cover with the hexagon socket screws. 10.3.2 Opening and closing the service door IMPORTANT! The hood for the MPT-333 turnstile is equipped with a service door. The hood for the MPT-353 turnstile is equipped with two service doors. Opening the service door 1.
4 mm². Observe national provisions on line length and associated line cross-section. IMPORTANT! A mains cable is required for the MPT-333 turnstile and for the MPT- 353. Connect the mains supply cable for the MPT-353 to terminals X1 either on the right or left side of the support beam.
Page 96
MPT-333 and MPT-353 Electrical connection 3. Connect the mains cable to the terminals X1: L / N / PE in the support beam according to the following figures. ä Separate electrical circuit diagram. › Place mains cable properly in the support beam. Observe that the line does not get into any moving parts and is not crushed by the cover.
10.5 Connecting customer control lines IMPORTANT! For connecting the control lines provided by the customer, see separate document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)". 10.6 Connecting emergency opening contacts ä Separate electrical circuit diagram and document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)".
Electrical connection The access-control devices are connected to the control unit MGC. ä Separate electrical circuit diagram and document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)". 10.8 Checking the electrical connections After the electrical installation, check the following points: ›...
MPT-333 and MPT-353 Commissioning 11.3 Switching the pedestrian gate on and off NOTICE Fast restart! Switching the pedestrian gate on again too fast can lead to damage to the device! › Wait for at least 10 seconds after switching off the pedestrian gate before you switch the mains power on again.
11.4 Parameterising the pedestrian gate IMPORTANT! For parameterisation see separate document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)". Operation The operation of the pedestrian gate depends on the connected access-control devices, signal transmitters and signal receivers as well as on the parameterisation of the control unit.
MPT-333 and MPT-353 Cleaning and maintenance 13.2 Cleaning the pedestrian gate The cleaning interval essentially depends on the environmental conditions and the climate. NOTICE Aggressive cleaning aids and substances! Aggressive detergents and consumables may damage or destroy components, electric cables, or the coating of the pedestrian gate.
MPT-333 and MPT-353 Cleaning and maintenance 13.2.2 Cleaning support beam from the inside NOTICE Improper cleaning! Cleaning with a vapour or pressure-jet cleaner will damage or destroy electrical components and cables. › Never clean the support beam with vapour or pressure-jet cleaners.
Technician legibility. Check foundation fastening. Technician According to the operator Check emergency function. Operator Table 10: Maintenance schedule Corrective action IMPORTANT! For troubleshooting see separate document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)".
MPT-333 and MPT-353 Spare parts and repair Spare parts and repair NOTICE Wrong and faulty spare parts! Incorrect or defective spare parts can result in damage, malfunctions or total failure and also impair safety. › Use only the manufacturer's original spare parts.
Page 106
MPT-333 and MPT-353 Spare parts and repair 1. Disconnect the pedestrian gate from the power supply. Ensure that the system is powered down. Secure against reactivation. DANGER Danger to life, electrical voltage! 2. Loosen the connection line of the proximity sensor at the terminals.
MPT-333 and MPT-353 Converting the locking unit Converting the locking unit 16.1 Safety during conversion Qualification of personnel Cleaning and maintenance › Technician › Electrical specialist ä Page 12, Chapter 2.3.2. Personal protective equipment Wear the following personal protective equipment: ›...
Page 108
You can modify the locking unit into the "normally closed" configuration. You must then parameterise the turnstile for the "Normally closed" configuration in the "Gate HW" menu. For parameterisation see separate document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)". Characteristic Normally open...
Page 109
MPT-333 and MPT-353 Converting the locking unit 3. Remove magnet, e.g. magnet RL2. To do this, loosen both screws on the holder. 4. Loosen and remove the union nut. 5. Remove the 6 washers. Fig. 60: Remove magnet, washers and union nut 6.
Page 110
Locking unit configuration "Normally closed" 13. Parameterise the turnstile for the "Normally closed" configuration in the "Gate HW" menu on the control unit MGC. ä Separate document "Description of MGC control unit for MPT-333 and MPT-353 Full Height Turnstile (Doc.ID: 5817,0027)".
MPT-333 and MPT-353 Customer service Customer service Our customer service can be contacted for any technical advice. Information about the responsible contact person can be retrieved by telephone, fax, E-mail or via the Internet at any time, refer to manufacturer’s address on page 2.
MPT-333 and MPT-353 Decommissioning Decommissioning You disable the pedestrian gate in the following cases: › The pedestrian gate is installed at a different location. › The pedestrian gate will be decommissioned for more than 6 months. If you only want to deactivate the pedestrian gate for a short time, see the "Switching the pedestrian gate on and off"...
MPT-333 and MPT-353 Disassembly and disposal Disassembly and disposal 19.1 Safety during disassembly and disposal Qualification of personnel › Technician › Electrical specialist ä Page 12, Chapter 2.3.2. Personal protective equipment Wear the following personal protective equipment: › Work clothes ›...
EU-Declaration of Conformity The manufacturer MAGNETIC AUTOCONTROL GmbH hereby declares for the product supplied by him: Designation Full height turnstile Type MPT-3*3 From serial number 10631404 The conformity according to: Directive 2006/42/EC (Machine directive) amended by 2009/127/EC Directive 2014/30/EU (EMC directive)
For base frame FURA T3 ......43 Changes ............10 For base frame FURA T5 ......63 Cleaning ..........101, 102 For direct mounting MPT-333 ....45 Commissioning ..........99 For direct mounting MPT-353 ....65 Connecting rod Function............27 MPT-353 ..........
Page 116
MPT-333 and MPT-353 Index Mains cable Service door Connecting ..........95 Close ..........93, 94 Maintenance schedule ......104 MPT-333 ..........25 MGC control unit MPT-353 ..........26 Technical data ......... 24 Open ..........93, 94 Misapplications ........... 10 Spare parts ..........105 Modifications ..........