The set temperature rise 1℃ per hour. Two hours later, the set temperature will maintain as a
constant and the fan speed is kept at low speed.
9.12.3 Heating:
The set temperature decrease 1℃ per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
9.12.4 Auto:
After an hour running under economic mode, the set temp will rise 1℃, if it is under cooling mode; the
set temp will decrease 1℃,if it is under heating mode; the set temp will be changeless, if it is under
fan-only mode; the condition will be the same after the air conditioner running under economic mode
after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7
hours the unit stops.

9.13 Auto restart function

In case of a sudden power failure, this function automatically sets the unit to previous settings before
the power failure when power returns.

9.14 Ionizer (air clean) function

9.14.1 Ionizer (air clean) function is effected when the unit is working and controlled by the remote
controller.
9.14.2 This function is active when the unit received the signal from the remote controller first time and
inactive when received the signal again. Repeat this circle when received signal again.
9.14.3 This function is working only when the indoor fan is working.
9.14.3 This function will not stop when the working mode changed, and be inactive when the unit shut
Service manual